Software Increment Release Notes ================================ Increment ID: ACN03N16 Date created: September 13, 1999 CSR number: 50124608 Title: This patch addresses two WorldCom DMS-X issues Detailed Description of Increment: ---------------------------------- 1) When link 0 is failed lines on even LSGs can't break dial tone. And when link 3 is failed you can not break dial tone on odd LSGs. This is a modification of SCT.6. 2) The AccessNode does not send a message to the DMS-100 when the links between it and its VMs are down. This will add two new messages which will be sent to update the DMS-100. This is based on update PRK.2. System Configuration / Shelf Type Requirements: ----------------------------------------------- This increment is applicable to all AccessNode configurations and shelf types when hosted by the DMS-X interface. Increments Needed: ------------------ ACN00N16 ******** PLEASE NOTE ******* If you have FA processors (32 meg) you must have ACN07N16 applied before applying ACN01N16. If you currently do not have FA processors in the system, and will not be adding any, then you do not need to apply ACN07N16 ACN07N16 **************************** ACN01N16 ACN02N16 Loads Affected: --------------- APU: ACCL16DI, ACCD16DI, ACCV16DI, ATBL16DI Installation Instructions: -------------------------- Download increment from the Web. Either a) download the increment directly to the /iswd directory on the OPC. b) download the increment to tape and insert into the OPC tape drive. Start up Incremental SW Del. from the Software Admin toolset on the OPC. Deliver the increment. Apply the increment. Test Instructions: ------------------ For part 1 of this patch (modified SCT.6 functionality): 1. verify that LC2.5 and 40 work properly. 2. disconnect link#0 physically. 3. try to make a call from LC2. Results: we heard DT but no digit was accepted.(i.e. after push a digit, still DT.) 4. try to make a call from LC5. Results: we heard DT but no digit was accepted. 4. try to make a call from LC40 to LC2. Results: no problem. 5. re-connect link#0. 6. verify that LC2,5 and 40 work properly. 7. disconnect link#3 physically. 8 try to make a call from LC2 to LC5. Results: no problem. 9 try to make a call from LC5 to LC40. Results: no problem. 10 try to make a call from LC40. Results: we heard DT but no digit was accepted. 11 re-connect link#3. 12 verify that LC2,5 and 40 work properly. For part 2 of this patch(PRK.1 functionality): Change the link from VM to HDT to OOS and verify the line state on CM becomes LMB. Bring the link back in service and verify the line state in CM becomes IDL. Display: -------- INCREMENT ID - ACN03N16 TITLE: DESCRIPTION: NE# STATUS NE# STATUS _____ _____________________ _____ _____________________ 49 DELIVERED 50 DELIVERED Apply: ------ **************************** * Summary Of Apply Command * **************************** The command was not aborted. The processors involved: APU Results for NE 49 Increment ID: ACN03N16 Processor Status ----------------------------------------- APU Success **************************** * Summary Of Apply Command * **************************** The command was not aborted. The processors involved: APU Results for NE 50 Increment ID: ACN03N16 Processor Status ----------------------------------------- APU Success Remove: ------- ***************************** * Summary Of Remove Command * ***************************** The command was not aborted. The processors involved: APU Results for NE 49 Increment ID: ACN03N16 Processor Status ----------------------------------------- APU Success ***************************** * Summary Of Remove Command * ***************************** The command was not aborted. The processors involved: APU Results for NE 50 Increment ID: ACN03N16 Processor Status ----------------------------------------- APU Success