Software Increment Release Notes ================================ Increment ID: ACN07N16 Date created: 10/28/99 CSR number: 59009742 Title: Correct problem with ISD to allow patching of FA procs. Detailed Description of Increment: ---------------------------------- This patch will fix the patcher database on the NE for FA processors. This will allow patcher to correctly identify patches, enabling them to be applied and removed. System Configuration / Shelf Type Requirements: ----------------------------------------------- This increment is applicable to all Access Node configurations with FA processors. Increments Needed: ------------------ ACN01N16 ********* PLEASE NOTE ******** You must attempt to apply ACN01N16 before applying this patch (ACN07N16). If you have applied ACN01N16 and then removed it, you must first apply this patch (ACN07N16) and then re-apply ACN01N16. Removal of these patches must be done in reverse order, starting with the highest patch. ****************************** Loads Affected: --------------- APU - ACCV16DI, ACCD16DI Installation Instructions: -------------------------- Download increment from the Web: Either a) download the increment directly to the /iswd directory on the OPC. b) download the increment to tape and insert into the OPC tape drive. Start up Incremental SW Del. from the Software Admin toolset on the OPC. Deliver the increment: 1) Select Deliver an Increment. 2) Type y to verify your selection. Verify the increment: 1) From the ISD main menu, select Display Increments. 2) Select Display to Screen. 3) Verify the increment delivered have the correct Title and Description. Also verify that their status is "READY TO APPLY". NOTE: If the increment is a Linecard only increment, the status will be "LOAD DELIVERED". 4) Press any key to return to the main menu. Apply the increment: 1) From the ISD main menu, select Apply an Increment. 2) In the list, select the number next to the increment you delivered. 3) Select one of these options: 1) Apply to ALL NEs (to set the increment fully into the system) 2) Trial on one NE (to test the increment to ensure that it causes no problems) If you select option 2, a list of NEs in the span of control appears. From the list of NEs, select the number next to the one you want to test. A confirmation screen appears. 4) Type y to verify your selection. 5) When the application is complete, press any key to scroll through the Summary screesn until you return to the main menu. 6) From the main menu, select Display Increments. 7) Select Display to Screen. 8) Verify that the status next to each NE now reads "APPLIED" (or "TRIAL APPLIED" if you chose to run a test in step 3 above). Test Instructions: ------------------