Software Increment Release Notes ================================ Increment ID: I02A1730 Date created: April 7, 2000 CSR number: ________ Title: Improve UE9000 Calling and Robustness and HK POTS support Detailed Description of Increment: ---------------------------------- The target platform for this ISD is the software on the UE9000 TDM circuit pack. The first part of this ISD improves disconnect time on the UE9000 POTS 24 multi-circuit line cards. Without this ISD and with the wrong settings at the DMS-100, it may take up to 2 seconds to disconnect a phone call. This ISD makes the disconnect immediate. The second part of this ISD removes a defect in the TDM login tool. This tool is used by design to gather data from field systems. It was determined that the tool had a defect that could cause the TDM to fail and not switch activity. This ISD fixes both the defect in the TDM login tool and adds robustness to the TDM activity switches. The final part of this ISD makes the TDM support the Hong Kong line card. It now recognizes and initializes the Hong Kong line card appropriately. System Configuration / Shelf Type Requirements: ----------------------------------------------- UE9000 Increments Needed: ------------------ I01A1730 Loads Affected: --------------- TDM Installation Instructions: -------------------------- Download increment from the Web: Either a) download the increment directly to the /iswd directory on the OPC. b) download the increment to tape and insert into the OPC tape drive. Start up Incremental SW Del. from the Software Admin toolset on the OPC. Deliver the increment: 1) Select Deliver an Increment. 2) Type y to verify your selection. Verify the increment: 1) From the ISD main menu, select Display Increments. 2) Select Display to Screen. 3) Verify the increment delivered have the correct Title and Description. Also verify that their status is "READY TO APPLY". NOTE: If the increment is a Linecard only increment, the status will be "LOAD DELIVERED". 4) Press any key to return to the main menu. Apply the increment: 1) From the ISD main menu, select Apply an Increment. 2) In the list, select the number next to the increment you delivered. 3) Select one of these options: 1) Apply to ALL NEs (to set the increment fully into the system) 2) Trial on one NE (to test the increment to ensure that it causes no problems) If you select option 2, a list of NEs in the span of control appears. From the list of NEs, select the number next to the one you want to test. A confirmation screen appears. 4) Type y to verify your selection. 5) When the application is complete, press any key to scroll through the Summary screesn until you return to the main menu. 6) From the main menu, select Display Increments. 7) Select Display to Screen. 8) Verify that the status next to each NE now reads "APPLIED" (or "TRIAL APPLIED" if you chose to run a test in step 3 above). IF THE INCREMENT INVOLVES THE APU YOU MUST DO THE FOLLOWING STEP Dump the image: 1) From the ISD main menu, select Dump an APU Image. 2) Select one of the valid load types that can be dumped. 3) Select one of the valid NEs matching your previous parameters. 4) Type y to verify your selection. 5) When the image is complete, press any key to return to the main menu. Test Instructions: ------------------