Software Increment Release Notes ================================ Increment ID: I121730 Date created: September 13, 2000 CSR number: CN90110, CT92550 Title: ------ ANX visibility in INM view & UE9000 increment improvements Effect on Traffic: ------------------ This increment has no effect on traffic. (See Special Instructions) Detailed Description of Increment: ---------------------------------- The increment solves the problem of ANXs randomly disappearing from the INM view. The disappearances occurred in two situations: - On very large span of controls - Where there were duplicate NE IDs. This increment also improves the application process when incrementing the UE9000 shelf. System Configuration / Shelf Type Requirements: ----------------------------------------------- This increment must be applied to all AN17.30 AccessNode configurations and shelf types. This increment affects the OPC load. Prerequisite Increments Required: --------------------------------- Increments I1A1730 - I11A1730 must be successfully applied prior to the application of this increment. Loads Affected: --------------- OPC - ACNL17BZ Special Instructions: --------------------- *** PLEASE NOTE *** After successfully installing this increment, you MUST EXIT the ISD tool before loading another increment. Failure to exit ISD will result in using the old ISD software and this increment will NOT be effective. Installation Instructions: -------------------------- Download increment from the Web: Either a) download the increment directly to the /iswd directory on the OPC. b) download the increment to tape and insert into the OPC tape drive. Start up Incremental SW Del. from the Software Admin toolset on the OPC. Deliver the increment: 1) Select Deliver an Increment. 2) Type y to verify your selection. Verify the increment: 1) From the ISD main menu, select Display Increments. 2) Select Display to Screen. 3) Verify the increment delivered has the correct Title and Description. Also verify that their status is "READY TO APPLY". NOTE: If the increment is a Linecard only increment, the status will be "LOAD DELIVERED". 4) Press any key to return to the main menu. Apply the increment: 1) From the ISD main menu, select Apply an Increment. 2) In the list, select the number next to the increment you delivered. 3) When complete the status should be 'Success'. Press any key to get back to the main menu. 4) Exit the ISD tool before delivering another increment, as specified in the Special Instructions above. Test Instructions: ------------------ For ANXs on INM view fix: After installing patch, go to the INM view and verify that all ANXs are now visible. For the UE9000 increment application process fix: After installing patch, UE9000 increments should no longer timeout and require manual intervention during the application phase of installation.