Software Increment Release Notes ================================ Increment ID: I14A1730 Date created: July 26, 2000 CSR number: 10339957 Title: DTAP Card fails on DS0 transition. Detailed Description of Increment: ---------------------------------- When the DS0 facilities assigned to the DTAP are busied and returned-to-service, the DTAP card may fail. When it does fail, it does not recover for at least 30 minutes. This patch adds code to recover the DTAP card when this occurs. System Configuration / Shelf Type Requirements: ----------------------------------------------- Any system equipped with a DTAP card. Increments Needed: ------------------ All previous increments. Loads Affected: --------------- APU Installation Instructions: -------------------------- Download increment from the Web: Either a) download the increment directly to the /iswd directory on the OPC. b) download the increment to tape and insert into the OPC tape drive. Start up Incremental SW Del. from the Software Admin toolset on the OPC. Deliver the increment: 1) Select Deliver an Increment. 2) Type y to verify your selection. Verify the increment: 1) From the ISD main menu, select Display Increments. 2) Select Display to Screen. 3) Verify the increment delivered have the correct Title and Description. Also verify that their status is "READY TO APPLY". NOTE: If the increment is a Linecard only increment, the status will be "LOAD DELIVERED". 4) Press any key to return to the main menu. Apply the increment: 1) From the ISD main menu, select Apply an Increment. 2) In the list, select the number next to the increment you delivered. 3) Select one of these options: 1) Apply to ALL NEs (to set the increment fully into the system) 2) Trial on one NE (to test the increment to ensure that it causes no problems) If you select option 2, a list of NEs in the span of control appears. From the list of NEs, select the number next to the one you want to test. A confirmation screen appears. 4) Type y to verify your selection. 5) When the application is complete, press any key to scroll through the Summary screesn until you return to the main menu. 6) From the main menu, select Display Increments. 7) Select Display to Screen. 8) Verify that the status next to each NE now reads "APPLIED" (or "TRIAL APPLIED" if you chose to run a test in step 3 above). IF THE INCREMENT INVOLVES THE APU YOU MUST DO THE FOLLOWING STEP Dump the image: 1) From the ISD main menu, select Dump an APU Image. 2) Select one of the valid load types that can be dumped. 3) Select one of the valid NEs matching your previous parameters. 4) Type y to verify your selection. 5) When the image is complete, press any key to return to the main menu. Test Instructions: ------------------ 1.) Busy all DS0s assigned to the DTAP card. 2.) Return all DS0s assigned to the DTAP card to service. 2.) Verify that the DTAP card is inservice after 5 minutes.