Software Increment Release Notes ================================ Increment ID: I30A1730 Date created: 07/20/2001 Title: ------ Line Loop Testing Enhancements Effect on Traffic / Warnings: ----------------------------- This increment has no effect on traffic. Detailed Description of Increment: ---------------------------------- 1. This increment corrects an issue where Line Loop Testing (LLT) commands that utilized the Integrated Remote Test Unit (IRTU) would not work properly when the line card had been remapped with the DMSPROV tool and was on DMS Host two or higher. 2. This increment allows IRTU Line Cards (ILC) to function properly when remapped with the DMSPROV tool. 3. This increment adds functionality so that ILC lines can be provisioned on the UE9000 shelf. 4. This increment corrects an issue where line cards were having intermittent dialtone because they were being incorrectly convicted as babblers. 5. This increment gets rid of misleading error messages during a UE9000 shelf download. System Configuration / Shelf Type Requirements: ----------------------------------------------- This increment must be applied to all AN17.30 AccessNode configurations and shelf types. This increment affects the APU. Prerequisite Increments Required: --------------------------------- Increments I01A1730 - I29A1730 must be successfully applied prior to application of this increment. Loads Affected: --------------- APU: ACCL17AS Special Instructions: --------------------- None Installation Instructions: -------------------------- Please refer to the Incremental Software Delivery Users Guide for general installation instructions. This document may be obtained from either the AccessWeb ISD web site (https://www23.nortelnetworks.com/ACCESS_OPTICAL/esd/), where the AccessNode increments are located, or you may order it through your Nortel Account Manager or Order Manager. The document number for the Incremental Software Delivery Users Guide is P0934362. Test Instructions: ------------------ Issue 1) Ensure all LLT commands from the switch work properly for remapped line cards that connect to DMS host two or higher. Issue 2) Provision ILC lines on a remapped slot and ensure they work properly. Issue 3) Make sure that ILC lines can be provisioned on the UE9000 shelf. ILC lines will only come In-Service (IS) if the Multi-Line Circuit (MLC) slot is empty. Issue 4) Testing not required. Issue 5) Testing not required.