Software Increment Release Notes ================================ Increment ID: I34A1730 Release: AN1730 Date created: January 17th, 2002 Increment Type: APU Title: Spurious APC detection and Upgrade enhancements ---------------------------------------------------------------------- Following is a list of changes included in this Increment. See below for more details. 1. Prevent spurious APC detection on simplex processor systems. 2. Upgrade enhancements. ---------------------------------------------------------------------- 1. Prevent spurious APC detection on simplex processor systems. * Description: An intermittent problem could cause the active APC to create the instance of a false mate processor on a simplex system due to a spurious APC detection. * Impact: Raises loss of data synchronization and mate communication alarms as well as processor unequipped alarm. If the condition exists, it could also cause problems during an Upgrade. * Pre-Increment work-around: The alarms can be turned off through the Proc Equipment Alarm Provisioning menu in the AccessNode NE UI. This will prevent the alarms from being reported to the user. 2. Upgrade enhancements. * Description: Introduce feature enhancements to allow for AN17.30 to AN19.05 upgrades. * Impact: Without this increment the overall time to complete an AN17.30 to AN19.05 Upgrade will be increased by approximately 30 minutes. * Pre-Increment work-around: There is no work around available. System Configuration / Shelf Type Requirements: ---------------------------------------- This increment is applicable to all AN17.30 AccessNode configurations and shelf types. This increment affects APU processor(s). Increments Needed: ---------------------------------------- Increments I01A1730 through I33A1730 must be successfully applied prior to application of this increment Loads Affected: ---------------------------------------- APU: ACCL17AS APU: ATBL17AS Special Instructions: ---------------------------------------- Note: if you are applying this patch to a TBM shelf you may need to do a restart warm on the TBM shelf after applying the patch, to fix an issue where you will be unable to take an image of the TBM shelf or do a database backup. Installation Instructions: ---------------------------------------- Please refer to the Incremental Software Delivery Users Guide for general installation instructions. This document may be obtained from either the patch web site (http://www.zhone.com/support/patches), where the AccessNode increments are located, or you may order document PO934362 through your Zhone Technologies Account Manager or Order Manager.