Software Increment Release Notes ================================ Increment ID: I36A1730 Release: AN1730 Date created: 5-9-2002 Increment Type: OPC Title: OPC: Facility Assignment Manager and timeout value changes. ---------------------------------------------------------------------- Following is a list of issues addressed in this Increment. See below for more details. 1. Unable to assign facilities for STS1 card to TIC connections. 2. Timeout values changed for Connection and Provisioning Managers. ---------------------------------------------------------------------- 1. Unable to assign facilities for STS1 card to TIC connections. * Description: For our customers using the STS1 card, the Connection Manager would not allow TR08 or Tandem facility assignments for STS1 card to TIC connections. * Impact: Unable to assign TR08 or Tandem facilities on STS1 card to TIC connections. This condition exists for both TIC and ATIC cards. * Pre-Increment work-around: None. 2. Timeout values changed for Connection and Provisioning Managers. * Description: For AN17, any operation requiring a Facility Assignment query could fail during periods of high Network Element utilization. The common operations that generate Facility Assignment queries are the opening of the Provisioning Manager and performing a Facility Assignment query from the Connection Manager. The change included in this increment changes the timeout value from 2 to 5 minutes, as well as providing a method to change the timeout value on the OPC with Zhone GSS support. * Impact: The Provisioning Manager would fail to open at times, as well as a failure to perform Facility Assignment queries or to open the Facility Assignment tool. The failure of the tools to open depends on provisioning on the nodes in the OPC span of control, and how busy the Network Elements are at the time of the action. * Pre-Increment work-around: Retry the operation. System Configuration / Shelf Type Requirements: ---------------------------------------------------------------------- This increment is applicable to all AN17.30 AccessNode configurations and shelf types. This increment affects OPC processor(s). Increments Needed: ---------------------------------------------------------------------- Increments I01A1730 through I351730 need to be successfully applied prior to application of this increment. Loads Affected: ---------------------------------------------------------------------- After successful application of this increment, the OPC load will be: ACNL17BZ Special Instructions: ---------------------------------------------------------------------- None. Installation Instructions: ---------------------------------------------------------------------- Please refer to the Incremental Software Delivery Users Guide for general installation instructions. This document may be obtained from either the AccessWeb ISD web site located on the Zhone home page at (http://www.zhone.com/support/patches/index.html), or you may order document 830-00374-01 from your Zhone Technologies Account Manager or Order Manager.