Software Increment Release Notes ================================ Increment ID: I40A1730 Release: AN1730 Date created: 5-1-2004 Increment Type: APU Title: Upgrade enhancement, TCSFWDL, ISD tool enhancement. ---------------------------------------------------------------------- *** WARNING: Please refer to the following Pre-installation *** *** special instructions before applying this Increment. *** ---------------------------------------------------------------------- Following is a list of issues addressed in this Increment. See below for more details. 1. Entity set robustness to eliminate restart reloads during upgrades. 2. Remove password protection for TCSFWDL. 3. ISD tool enhancement. ---------------------------------------------------------------------- *** Pre-installation Special Instructions: ---------------------------------------------------------------------- Some customers may have had special debug increment I99A1730 applied to their systems. In order for I40A1730 to apply properly, I99A1730 must first be removed. To determine if this is applicable to your OPC span of control, use the 'Display Increments' option in the ISD tool to display all increments. If I99A1730 exists, you must use the 'Remove An Increment' option to remove I99A1730 PRIOR TO applying I40A1730. Failure to remove increment I99A1730 will result in a patching error and I40A1730 will not apply. ---------------------------------------------------------------------- 1. Entity set robustness to eliminate restart reloads during upgrades. * Description: An upgrade issue has been discovered where swacts to the new software release could drop all traffic. This issue has been seen on some sites when performing upgrades during high traffic periods. * Pre-Increment Impact and work-around: All calls could drop during the upgrade swact to the new load. The system will automatically recover after the restart reload completes. Care should be exercised to upgrade the system during low traffic periods, as recommended in the Upgrades documentation. ---------------------------------------------------------------------- 2. Remove password protection for TCSFWDL. * Description: This increment takes away the requirement for the password of the day from the TCSFWDL tool. This tool is used when upgrading the firmware on OC12 VTBM circuit packs (NT7E05 series). * Pre-Increment Impact and work-around: Contact Zhone GSS for the password of the day at 1-877-Zhone-20 (1-877-946-6320). ---------------------------------------------------------------------- 3. ISD tool enhancement. * Description: When incrementing the AccessNode ABM processor, an issue was raised where large increments would indicate that they had been applied to the active processor, but actually had not. * Pre-Increment Impact and work-around: Performing a warm restart on the active ABM processor prior to applying a large ABM increment will resolve the issue. ---------------------------------------------------------------------- Increments Needed: ---------------------------------------------------------------------- Increment I01A1730 through I39A1730 needs to be successfully applied prior to application of this increment. ---------------------------------------------------------------------- Loads Affected: ---------------------------------------------------------------------- ABM: ACCL17AS TBM: ATBL17AS ---------------------------------------------------------------------- Installation Assistance: ---------------------------------------------------------------------- Please refer to the Incremental Software Delivery Users Guide for general installation instructions. This document may be obtained from either the AccessWeb ISD web site located on the Zhone web page at (http://www.zhone.com/support/patches/index.html), or you may request document 830-00374-01 from your Zhone Technologies Account Manager or Order Manager. Issues with this increment should be directed to Zhone Global Services and Support at 1-877-ZHONE-20 (1-877-946-6320).