Software Increment Release Notes ================================ Increment ID: I13A1800 Date created: 10/18/2000 Title: ------ Dead System Recovery, Cluster Inv, Conn Mgr & TL1 improvements Effect on Traffic: ------------------ No effect on traffic. Detailed Description of Increment: ---------------------------------- This increment provides the following improvements: 1. During dead system recovery and initial power-up, the load booting process is improved. Timeouts and reloading are avoided. Also, the information displayed in the reboot load manager is now accurate. 2. Cluster inventory was displaying erroneous data for the ANX linecard services. This increment now allows the linecard services of the ANX to be displayed correctly. 3. The Cluster Inventory display was also missing data for some line card slots. Improvements have been made to show all data, including slots with no cards but service provisioned, and slots with cards with no service provisioned. 4. During NeId renumbering, sts-n-line objects are now renumbered correctly. In addition, the NeId of the other Ne in the point to point configuration is now used to modify the connection database of that Ne. 5. This increment corrects the issue where the error message "Connection Rollover in Progress" was displaying on the connection manager after a node was added to a VT managed ring. The message will need to be cleared manually, however, it will not occur again. 6. The user will able to configure TL1 over TCP/IP from OPCUI, and will not be required to go to a UNIX shell. System Configuration / Shelf Type Requirements: ----------------------------------------------- This increment must be applied to all AN18.00 AccessNode configurations and shelf types. This increment effects the Operations Controller (OPC). Prerequisite Increments Required: --------------------------------- Increments I01A1800 through I12A1800 must be successfully applied prior to application of this increment. Loads Affected: --------------- OPC:ACNL18AX Special Instructions: --------------------- If the system is configured to use TL1 over TCP/IP, then the TL1X25SM process must be restarted. The new executable will be in effect once the TL1X25SM MSR is restarted. Please contact Nortel Technical Support for instructions and help with this process. Installation Instructions: -------------------------- Download increment from the Web: Either a) download the increment directly to the /iswd directory on the OPC. b) download the increment to tape and insert into the OPC tape drive. Start up Incremental SW Del. from the Software Admin toolset on the OPC. Deliver the increment: 1) Select Deliver an Increment. 2) Type y to verify your selection. Verify the increment: 1) From the ISD main menu, select Display Increments. 2) Select Display to Screen. 3) Verify the increment delivered has the correct Title and Description. Also verify that the status is "READY TO APPLY".