Software Increment Release Notes ================================ Increment ID: I15A1800 Date created: October 24, 2000 CSR number: TDM (UE9000) fixes for C-Notch test and CSC forward disconnect Title: ------ UE9000 fixes (C-Notch test, CSC forward disconn., others) Effect on Traffic: ------------------ Calls in progress will not be dropped. Calls can not be originated for 30 seconds while the TDM executes a warm restart. Detailed Description of Increment: ---------------------------------- This increment provides fixes for the following issues: 1. Fixes problem with current regulation during LLT causing C-Notch test to fail 2. Fixes CSC forward disconnect problem 3. Fixes TDM diags 4. Allows Line Card reset on SI card pulls when jack access is up 5. Fixes card insert swerr on 8+8 and 10+10 MLCs 6. Ensures PEC, serial number and CLEI are fixed length System Configuration / Shelf Type Requirements: ----------------------------------------------- This increment is applicable to AccessNode configurations with UE9000 shelves. Prerequisite Increments Required: --------------------------------- I01A1800 through I14A1800 Loads Affected: --------------- TDM: ANTDM18BL Installation Instructions: -------------------------- NOTE: Application of this patch will take at least one hour. Application of this patch to spans of control that have more than 5 NEs that have UE9000 shelves may take several hours. Do NOT exit ISD or abort the process. Additionally for large spans of control, the patch application may fail. Download increment from the Web: Either a) download the increment directly to the /iswd directory on the OPC. b) download the increment to tape and insert into the OPC tape drive. Start up Incremental SW Del. from the Software Admin toolset on the OPC. Deliver the increment: 1) Select Deliver an Increment. 2) Type y to verify your selection. Verify the increment: 1) From the ISD main menu, select Display Increments. 2) Select Display to Screen. 3) Verify the increment delivered has the correct Title and Description. Also verify that their status is "READY TO APPLY". NOTE: If the increment is a Linecard only increment, the status will be "LOAD DELIVERED". 4) Press any key to return to the main menu. Apply the increment: 1) From the ISD main menu, select Apply an Increment. 2) In the list, select the number next to the increment you delivered. 3) Select one of these options: 1) Apply to ALL NEs (to set the increment fully into the system) 2) Trial on one NE (to test the increment to ensure that it causes no problems) If you select option 2, a list of NEs in the span of control appears. From the list of NEs, select the number next to the one you want to test. A confirmation screen appears. NOTE: Trial apply does not change the catalogue file in the OPC. If you wish to trial apply, you must first perform the following steps at the NE that is being trial applied: >quit all >ueupgci >autoupgs off Executing these commands turns the auto upgrade for the TDMs to off. Performing a restart will turn the auto upgrade back on. A TDM firmware mismatch alarm will occur. 4) Type y to verify your selection. 5) When the application is complete, press any key to scroll through the summary screen until you return to the main menu. 6) From the main menu, select Display Increments. 7) Select Display to Screen. 8) Verify that the status next to each NE now reads "APPLIED" (or "TRIAL APPLIED" if you chose to run a test in step 3 above). NOTE: If the patch FAILS (status with the Incremental Software Delivery tool), execute the following commands at the NE for which the patch fail state appears: >quit all >ueupgci >getcatalogue REL_1800 >upgradetdm The TDM upgrade will take approximately 45 minutes. If the communication between the OPC and the NE is an OMC link, the TDM download may take more than one hour. Up to four NEs can be upgraded manually simultaneously. Test Instructions: ------------------