Software Increment Release Notes ================================ Increment ID: I17A1800 Date created: 05/29/01 Title: ------ Address Increment Application Timeout Issue On ABM Shelf Effect on Traffic / Warnings: ----------------------------- The application of this increment has no effect on traffic. Detailed Description of Increment: ---------------------------------- When a very large software increment is applied to an Access Bandwidth Manager (ABM) shelf, it is possible for an application timeout to occur. In this situation, messages between the Incremental Software Delivery (ISD) process and the ABM increment application process may be lost or interpreted incorrectly. This increment adds message buffer enhancements, and increases the timeout value for increment application. System Configuration / Shelf Type Requirements: ----------------------------------------------- This increment must be applied to all AN18.00 AccessNode configurations and shelf types. This increment affects the Active Processor Unit (APU). Prerequisite Increments Required: --------------------------------- Increments I01A1800 - I16A1800 must be successfully applied prior to application of this increment. Loads Affected: --------------- APU: ACCL18BC Special Instructions: --------------------- None Installation Instructions: -------------------------- Please refer to the Incremental Software Delivery Users Guide for general installation instructions. This document may be obtained from either the AccessWeb ISD web site (https://www23.nortelnetworks.com/ACCESS_OPTICAL/esd/), where the AccessNode increments are located, or you may order it through your Nortel Account Manager or Order Manager. The document number for the Incremental Software Delivery Users Guide is P0934362. Test Instructions: ------------------ No field testing of this increment is required.