Software Increment Release Notes ================================ Increment ID: I28A1800 Date created: December 14, 2001 Title: ------ This increment addresses ANX remote testing issues, STS-1 ping audits, Line Card diagnostics from the Network Element and the Switch, command handler TRAPs, and UE9000 specific SWERRs. Effect on Traffic / Warnings: ----------------------------- None. Detailed Description of Increment: --------------------------------- WARNING - After this increment is applied, a valid APU image MUST be taken. Consult the Incremental Software Delivery Users Guide (P0934362) for details on how to dump an APU image. 1. In AN18 an issue was discovered where testing for ANX 56 was not possible. In addition, some ANXs could return misleading test results if not examined closely by the Telco. This patch increment resolves these occurrences by making some changes to the ANX Remote Test Unit Command Interface(ANXRTUCI). 2. The STS-1 ping audit has been made more robust to address STS-1 failures caused by pipe interrupts being permanently disabled. The audit has been improved to enable all STS-1 pipe interrupts when the system does not receive a response from a ping. 3. An issue was discovered that prevented NE and switch line card diagnostics from being run after two consecutive failures. The test session ids were not being deallocated properly after a diag failure. This increment addresses the issue. 4. The increment improves system stability as described below: o allows the Network Element (NE) command interface as well as association to the NE to recover without user intervention in the unlikely event of a TRAP in the command handler. o addresses a UE9000 specific SWERR that was being caused by a process trying to unsuccessfully retrieve information concerning a line card. System configuration and shelf type requirements: ------------------------------------------------ This increment works with all AccessNode configurations and shelf types. Prerequisite Increments Required: -------------------------------- Increments I01A1800 through I27A1800 must be successfully applied prior to application of this increment. Loads Affected: -------------- APU: ACCL18BC Special Instructions: --------------------- None. Installation Instructions: -------------------------- Please refer to the Incremental Software Delivery Users Guide for general installation instructions. The Incremental Software Delivery Users Guide may be obtained through your Zhone Account Manager or Order Manager. The document number for the Incremental Software Delivery Users Guide is P0934362. Test Instructions: ------------------ 1. Using ANXRTUCI, provision test head equipment for ANX 56. Run some line and loop tests and verify the results. Note: For a complete description on how to provision an ANX system for line and loop testing, see "Configuring the ANX system interfaces and connections", in the AccessNode Express Commissioning and OAM&P NTP, 323-3051-220, in the AccessNode Express volume. 2. There is no test procedure for the STS-1 ping audit robustness. 3. Run several line card diagnostics from the NE as well as from the switch and make sure they run to completion.