Software Increment Release Notes ================================ Increment ID: I03A1905 Release: AN1905 Date created: 11-15-2002 Increment Type: OPC ---------------------------------------------------------------------- Title: OPC: Provisioning Manager and CONN-TACC command ---------------------------------------------------------------------- Following is a list of issues addressed in this Increment. See below for more details. 1. Allow Provisioning Manager to open without NE responses. 2. Correct the interpretation of parenthesis in the CONN-TACC command. ---------------------------------------------------------------------- 1. Allow Provisioning Manager to open without NE responses. * Description: In AN18, the Provisioning Manager moved to a TL1 interface to query existing Network Element provisioning. For reasons yet to be determined, the Network Element would not always respond in a timely manner to the query. As a result of the absence of a response, the Provisioning Manager would not open. This increment enhances the method of the tool opening and will now treat a non-responsive Network Element the same as one without association. This increment also enhances the "Update" button to re-issue the TL1 queries to all NE's, so that the button can be used to retry a Network Element without closing the tool. * Impact: Prior to this increment, the Provisioning Manager may fail to open. * Pre-Increment work-around: Direct TL1 commands can be used to provision facilities, DS0 services and manage cross-connects in AN1905. Refer to document 323-3001-190 for the TL1 users guide. ---------------------------------------------------------------------- 2. Correct the interpretation of parenthesis in the CONN-TACC command. * Description: This increment will correctly interpret and effect change on the NE when using values for tlpe and tlpf values when used with the CONN-TACC command. * Impact: Customers utilizing automated TL1-based test units such as the REACT test set could not change the dB levels contained in the tlpe and tlpf values. Refer to document 323-3001-190 for further information about the CONN-TACC command. * Pre-Increment work-around: The CHG-PRTPAR command can be used to change the port parameters. ---------------------------------------------------------------------- Increments Needed: ---------------------------------------------------------------------- Increments I01A1905 through I02A1905 need to be successfully applied prior to application of this increment. Loads Affected: ---------------------------------------------------------------------- After successful application of this increment, the OPC load will be: ACNL19GY Special Instructions: ---------------------------------------------------------------------- None. Installation Instructions: ---------------------------------------------------------------------- Please refer to the Incremental Software Delivery Users Guide for general installation instructions. This document may be obtained from either the AccessWeb ISD web site located on the Zhone web page at (http://www.zhone.com/support/patches/index.html), or you may request document 830-00374-01 from your Zhone Technologies Account Manager or Order Manager. Issues with this increment should be directed to Zhone Global Services and Support at 1-877-ZHONE-20 (1-877-946-6320).