Software Increment Release Notes ================================ Increment ID: I12A1905 Release: AN1905 Date created: 11-28-2003 Increment Type: APU Title: MLC failures during Protection Switching, ANX robustness ---------------------------------------------------------------------- Following is a list of issues addressed in this Increment. See below for more details. 1. MLC failures during Protection Switching Activities 2. ANX recovery robustness ---------------------------------------------------------------------- 1. MLC failures during Protection Switching Activities * Description: Primary optic protection switching may cause the UE9000 to momentarily fail Multiple-circuit Line Card (MLC) circuit packs. * Pre-Increment Impact and work-around: Tests have shown that action is not required by the customer to restore service to the impacted lines. However, under adverse conditions (such as several UE9000 shelves reporting multiple MLC failures) a more controlled recovery may speed overall system return to service. This can be accomplished by taking all the UE9000 shelves in trouble offline, and allowing each to recover in a serial fashion. ---------------------------------------------------------------------- 2. ANX recovery robustness * Description: Large ANX deployments (20 VM's per HDT and higher) have had issues where the LAIC's would both fail during different system actions. Such actions include the switching of processors at the ABM shelf, committing ANX increments from ISD as well as an event that causes the total loss of transport from the ABM shelf to the ANX systems. This increment improves ANX robustness by: - Providing CI commands which allow adjusting the number of ANX shelves recovered simultaneously following a ABM switch of activity, ABM restart or ANX loss of communication condition. Go to ANXRECOVERY command increment on the NE after applying this patch, and type "HELP" for more details. - Changing the default number of ANXs recovered at a time after a ABM switch of activity to 2. This value can also be changed from the ANXRECOVERY CI tool. * Pre-Increment Impact and work-around: Both LAIC packs could fail, causing a total system outage. Should both LAIC packs fail during a swact, the loss of transport or the application of an ANX increment, remove the LAIC packs and place the DS1 interfaces OOS at the fwpui. Place the LAIC packs back in the system, and place the DS1 facilities back IS one at a time. ---------------------------------------------------------------------- Increments Needed: ---------------------------------------------------------------------- Increments I01A1905 through I11A1905 need to be successfully applied prior to application of this increment. Loads Affected: ---------------------------------------------------------------------- After successful application of this increment, the APU loads will be: ACCL19HI ATBL19HI Special Instructions: ---------------------------------------------------------------------- None. Installation Instructions: ---------------------------------------------------------------------- Please refer to the Incremental Software Delivery Users Guide for general installation instructions. This document may be obtained from either the AccessWeb ISD web site located on the Zhone web page at (http://www.zhone.com/support/patches/index.html), or you may request document 830-00374-01 from your Zhone Technologies Account Manager or Order Manager. Issues with this increment should be directed to Zhone Global Services and Support at 1-877-ZHONE-20 (1-877-946-6320).