Software Increment Release Notes ================================ Increment ID: I17A1905 Release: AN1905 Date created: 01-21-2005 Increment Type: OPC Title: OPC: OPC INM ANX display and other fixes. ---------------------------------------------------------------------- This Increment addresses the following issues. See below for more details. 1. ANXs do not show consistently in the same place in INM display. 2. Provisioning Manager failure to open at times. 3. INM Connection Manager failure to open with large numbers of connections. ---------------------------------------------------------------------- 1. ANXs do not show consistently in the same place in INM display. * Description: INM view of ANXs change each time the OPC is rebooted. In AN1905, ANX voice modules will be renumbered on every OPC restart, Or any action which would cause the "TFED MSR" to restart. INM saves these numbers and re-uses them for each OPC session. This increment changes the OPC to also keep the ANX numbers constant over OPC restarts. The previously assigned numbers are no longer available at the OPC. After the application of this increment, one of two actions will be required by the customer to synchronize the OPC and INM: a. Re-arrange the INM ANX view by rebuilding the window, or b. Use a new tool at the OPC to reassign the ANX numbers. Care must be taken to reassign these numbers correctly. The customer must determine these numbers from his INM view. The OPC tool is located at /iws/tfe/tfetst. To obtain help on the tool: /iws/tfe/tfetst -h To renumber the ANXs: /iws/tfe/tfetst -r Contact Zhone GSS for questions/issues when running this tool. * Pre-Increment Impact and work-around: Rearrange INM ANXs within the view to the proper place. ---------------------------------------------------------------------- 2. Provisioning Manager failure to open at times. * Description: The Provisioning Manager fails to open at times. This increment fixes all the known causes for the tool not to open. * Pre-Increment Impact and work-around: Prior to this increment, the Provisioning Manager may fail to open. Direct TL1 commands can be used to provision facilities, DS0 services and manage cross-connects in AN1905. Refer to document 323-3001-190 for the TL1 users guide. ---------------------------------------------------------------------- 3. INM Connection Manager failure to open with large numbers of connections. * Description: The INM Connection Manager would fail to open once a significant number of connections were added. This change allows the INM Connection Manager to open with more connections. Contact GSS for finetuning of these changes if problems are still encountered after applying this increment. * Pre-Increment Impact and work-around: Connections would not be able to be queried, deleted, or added from the INM Connection Manager. OPC Connection Manager can be used to perform these actions on the local OPC. ---------------------------------------------------------------------- Increments Needed: ---------------------------------------------------------------------- Increments I01A1905 through I16A1905 need to be successfully applied prior to application of this increment. Loads Affected: ---------------------------------------------------------------------- After successful application of this increment, the OPC load will be: ACNL19GY Special Instructions: ---------------------------------------------------------------------- None. Installation Instructions: ---------------------------------------------------------------------- Please refer to the Incremental Software Delivery Users Guide for general installation instructions. This document may be obtained from either the AccessWeb ISD web site located on the Zhone web page at (http://www.zhone.com/cgi-bin/isd_external.cgi?AN1905), or you may request document 830-00374-01 from your Zhone Technologies Account Manager or Order Manager. Issues with this increment should be directed to Zhone Global Services and Support at 1-877-ZHONE-20 (1-877-946-6320).