Software Increment Release Notes ================================ Increment ID: I06A1960 Release: AN1960 Date created: 09-24-2004 Increment Type: UER Title: UE9K MLC Service Enhancements ---------------------------------------------------------------------- Following is a list of issues addressed in this Increment. See below for more details. 1. MLC line circuit testing. 2. MLC failures due to ringing an off-hook line. 3. MLC circuit pack missing false alarm at the UER BIP ---------------------------------------------------------------------- 1. MLC line circuit testing. * Description: A line circuit's test bus may be left active causing erroneous values when testing other line circuits on the same shelf. * Pre-Increment Impact and work-around: Before the application of this increment, it may be possible for a line circuit test bus to be left active on the MLC. The effect of this condition is that other line tests conducted on other circuits on the same shelf could return errored results. Re-seating the MLC is the only known work-around. ---------------------------------------------------------------------- 2. MLC failures due to ringing an off-hook line. * Description: When ringing is applied to a off-hook line card for a short period of time, the entire MLC may fail and reset. This occurrence should be relatively rare, as the terminating line must go off-hook in a window of a just few milliseconds. * Pre-Increment Impact and work-around: Before the application of this increment, the MLC would fail, reset and usually recover on its own. Follow-up testing of the MLC would not indicate any problems. No work-around is necessary, as the MLC would usually recover on its own. ---------------------------------------------------------------------- 3. MLC circuit pack missing false alarm at the UER BIP * Description: For the UER, the local shelf raises alarms for all linecard slots should there be no line card circuit pack installed. The circuit pack missing alarm is reported to the ABM shelf, which compares what cards have service provisioned on them and raises only those Circuit pack missing alarms on the ABM that have service on them. Prior to this increment, if the customer has the UER alarms wired to the BIP at the remote location (BipServer), the Major Circuit pack missing alarms are always present at the UER BIP. This increment will suppress at the UER BIP the alarms raised for missing line card packs that have no service provisioned. * Pre-Increment Impact and work-around: None. ---------------------------------------------------------------------- Increments Needed: ---------------------------------------------------------------------- Increments I01A1960 through I05A1960 need to be successfully applied prior to application of this increment. ---------------------------------------------------------------------- Loads Affected: ---------------------------------------------------------------------- After successful application of this increment, the TDM load will be: URTDM19KL ---------------------------------------------------------------------- Special Instructions: ---------------------------------------------------------------------- None. ---------------------------------------------------------------------- Installation Instructions: ---------------------------------------------------------------------- Please refer to the Incremental Software Delivery Users Guide for general installation instructions. This document may be obtained from either the AccessWeb ISD web site located on the Zhone web page at (http://www.zhone.com/support/patches/index.html), or you may request document 830-00374-01 from your Zhone Technologies Account Manager or Order Manager. Issues with this increment should be directed to Zhone Global Services and Support at 1-877-ZHONE-20 (1-877-946-6320).