Paradyne Firmware/Software/Hardware Release Notes

PARADYNE - PROPRIETARY

THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF PARADYNE CORPORATION AND IS NOT TO BE DISCLOSED OR USED EXCEPT IN ACCORDANCE WITH APPLICABLE AGREEMENTS.

Unpublished and Not for Publication

All Rights Reserved

Release Number: 02.01.16

Date: February, 17 2000

Release Type: Initial

Country Type: All

Release History

Affected Product Models

Release

Type

Date

Model

Description

02.01.16

Minor

12/21/99

6310-A1-XXX

6310-A2-XXX

PTF Release

02.01.08

Minor

06/09/99

6310-A1-XXX

6310-A2-XXX

PTF Release

02.01.05

Major

03/09/99

6310-A1-XXX

6310-A2-XXX

Initial Release

02.00.08

Minor

01/29/99

6310-A1-XXX

Initial Release

  1. Feature Enhancements / Functional Changes
  2. The 8310 and 6310-A1-XXX endpoint is now restricted to support of two drops per port.

    The 8312 and 6310-A2-XXX endpoint is now restricted to support of four drops per port.

  3. Resolved Customer Issues
  4. Action Request Number

    Description

    N/A

    Adding a 3rd and 4th MVL modem to a multi-drop configuration fails

    Notes: A fix was made to fix problems with the addition of 3rd and 4th drop in a multi-drop configuration. When powering up, it would take some drops an excessive amount of time to train up.

    This problem only affects customer deploying MVL multi-drop configuration and recommend you upgrade the endpoint firmware. In all other cases this is a non-issue

       
  5. Hardware Co-Requirements
  6. For proper operation with an 88xx/86xx DSLAM, this release requires an 8000 IP Conservative MCC, MCC Plus, or MCP with appropriate firmware:

    Card Type

    CCA #

    DSLAM

    8312 MVL 12 Port Card

    868-3426-8201, Rev .80A

    8610 and 8820

    8310 MVL 4 Port Card

    868-1246-8007, Rev 80A

    8600, 8800, 8810, 8820

    8000 IP Conservative MCC

    868-1010-81xx (xx = 00, 01, 02, …)

    8600, 8800, 8810

    8000 IP Conservative MCC Plus

    868-3882-80xx (xx = 00, 01, 02, …)

    8600, 8800, 8810

    8000 IP Conservative MCP

    868-3883-80xx (xx = 00, 01, 02, …)

    8610 and 8820

  7. Software Co-Requirements
  8. Card Type

    CCA #

    Firmware

    8312 MVL 12 Port Card

    868-3426-8201, Rev .80A

    02.01.46

    8310 MVL 4 Port Card

    868-1246-8007, Rev 80A

    02.01.39 or greater

    8000 IP Conservative MCC

    868-1010-81xx (xx = 00, 01, 02, …)

    04.00.32

    8000 IP Conservative MCC Plus

    868-3882-80xx (xx = 00, 01, 02, …)

    04.00.32

    8000 IP Conservative MCP

    868-3883-80xx (xx = 00, 01, 02, …)

    04.00.32

  9. Compatibility With Other Released Models

Since this is the initial release of this product, this section is not applicable.