Paradyne Firmware/Software/Hardware Release Notes

PARADYNE - PROPRIETARY

THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF PARADYNE CORPORATION AND IS NOT TO BE DISCLOSED OR USED EXCEPT IN ACCORDANCE WITH APPLICABLE AGREEMENTS.

Unpublished and Not for Publication

All Rights Reserved


Release Number: 04.01.01 Date: September 10, 2001
Release Type: Major Country Type: All
Release History
Affected Product Models
Release
Type
Date
Model
Description
04.01.01
Major
09/10/01
6310-A1-XXX
6310-A2-XXX
Major Release
03.01.01
Major
05/31/00
6310-A1-XXX
6310-A2-XXX
Major Release 
02.01.16 Minor 12/21/99
6310-A1-XXX
6310-A2-XXX
Minor Release 
02.01.08 Minor 06/09/99
6310-A1-XXX
6310-A2-XXX
Minor Release 
02.00.08 Major 01/29/99 6310-A1-XXX Initial Release 

         1. Feature Enhancements / Functional Changes

    This release provides the following additional key features:
    • Upgrade to new MVL DSP code rel 04.08.00 (afic and descrete)
    • On-Hook Voltage Drop Threshold values can be configured through CO

    2. Resolved Customer Issues
     
    Action Request Number
    Description
    None
     

         3. Hardware Co-Requirements
    For proper operation with an 88xx/86xx DSLAM, this release requires an 8000 IP Conservative MCC, MCC Plus, or MCP with appropriate firmware:
     
    Card Type CCA # DSLAM
    8310 MVL 4 Port Card 868-1246-8007, Rev. 80A 8600, 8800, 8610, 8810
    8312 MVL 12 Port Card 868-3426-8201, Rev .80A 8610, 8810, 8820
    8314 MVL 12 Port Card 868-4427-8000, Rev 80A 8820, 8620
    8000 IP Conservative MCC 868-1010-81xx (xx = 00, 01, 02, …) 8600, 8800, 8810
    8000 IP Conservative MCC Plus 868-3882-80xx (xx = 00, 01, 02, …) 8600, 8800, 8810
    8000 IP Conservative MCP 868-3883-80xx (xx = 00, 01, 02, …) 8610, 8820, 8620
          4.  Software Co-Requirements
     
    Card Type CCA # Minimum Firmware Requirements
    8310 MVL 4 Port Card 868-1246-8007, Rev. 80A 02.01.48
    8312 MVL 12 Port Card 868-3426-8201, Rev .80A 04.00.38** or greater
    8314 MVL 12 Port Card 868-4427-8000, Rev 80A 04.00.38** or greater
    8000 IP Conservative MCC 868-1010-81xx (xx = 00, 01, 02, …) M04.00.38 or greater
    8000 IP Conservative MCC Plus 868-3882-80xx (xx = 00, 01, 02, …) M04.00.38  or greater
    8000 IP Conservative MCP 868-3883-80xx (xx = 00, 01, 02, …) M04.00.38 or greater
        **Note: The port card must be Rel. 4.2.29 to have the ability to configure On-Hook Voltage Drop Threshold values.

5. Compatibility With Other Released Models
• 6310-A1 RTUs should not be used in a multi-point configuration on 8312 MVL line cards.

• 6310-A2 and 6310-A3 RTUs can be used in a multi-point configuration and can be mixed (i.e. , user can utilize -A2s and -A3s multi-dropped on the same port.)

• If loop length is greater that 8k better performance is achieved if there is at least one -A3 endpoint in the configuration.
 
 

NOTE: Do not load this firmware in an 6310-A3 modem.