Paradyne Firmware/Software/Hardware Release Notes

PARADYNE - PROPRIETARY

THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF PARADYNE CORPORATION AND IS NOT TO BE DISCLOSED OR USED EXCEPT IN ACCORDANCE WITH APPLICABLE AGREEMENTS.

Unpublished and Not for Publication

All Rights Reserved

Release Number: 03.01.02

Date: November 2, 2000

Release Type: Initial

Country Type: All

Release History

Affected Product Models

Release

Type

Date

Model

Description

03.01.02

Major

05/31/00

6310-A3-XXX

Initial Release

   
  1. Feature Enhancements / Functional Changes
  2. • Change to support -5, -8, and -11 TxOffHook Powers.

    • Incorporated new DSP code ver 04.01.00

  3. Resolved Customer Issues
  4. Action Request Number

    Description

    N/A

     

     

     

  5. Hardware Co-Requirements
  6. For proper operation with an 88xx/86xx DSLAM, this release requires an 8000 IP Conservative MCC, MCC Plus, or MCP with appropriate firmware:

    Card Type

    CCA #

    DSLAM

    8312 MVL 12 Port Card

    868-3426-8201, Rev .80A

    8610 and 8820

    8314 MVL 12 Port Card

    868-4427-8000, Rev 80A

    8820

    8000 IP Conservative MCC

    868-1010-81xx (xx = 00, 01, 02, …)

    8600, 8800, 8810

    8000 IP Conservative MCC Plus

    868-3882-80xx (xx = 00, 01, 02, …)

    8600, 8800, 8810

    8000 IP Conservative MCP

    868-3883-80xx (xx = 00, 01, 02, …)

    8610 and 8820

  7. Software Co-Requirements
  8. Card Type

    CCA #

    Firmware

    8312 MVL 12 Port Card

    868-3426-8201, Rev .80A

    02.01.48 or greater

    8314 MVL 12 Port Card

    868-4427-8000, Rev 80A

    02.01.48 or greater

    8000 IP Conservative MCC

    868-1010-81xx (xx = 00, 01, 02, …)

    04.01.21 or greater

    8000 IP Conservative MCC Plus

    868-3882-80xx (xx = 00, 01, 02, …)

    04.01.21 or greater

    8000 IP Conservative MCP

    868-3883-80xx (xx = 00, 01, 02, …)

    04.01.21 or greater

  9. Compatibility With Other Released Models

• 6310-A1 RTUs should not be used in a multi-point configuration on 8312 MVL line cards.

• 6310-A2 and 6310-A3 RTUs can be used in a multi-point configuration and can be mixed, ie. , user can utilize -A2s and -A3s multi-dropped on the same port.

• If loop length is greater that 8k better performance is achieved if there is at least one -A3 endpoint in the configuration.

Port Card to End Point Release Compatibility Matrix

Port Card

End Point Release

8310

2.0.XX

8310/8312

2.1.XX

8312/8314

3.1.XX

8312/8314

3.1XX

6310-A1/A2 2.0.XX

MD

C

 

 

 

6310-A1/A2 2.1.XX

 

MD

C

 

 

6310-A1/A2 3.1.XX

 

MD

C

MD

C

MD

C

6310-A3 3.1.XX

 

MD

C

MD

C

MD

C

 

 

 

 

 

MD = Multidrop supported C = Compatible Empty = Not compatible

 

NOTE: Do not load this firmware in an 6310-A1 or 6310-A2 modem.