Paradyne Firmware/Software/Hardware Release Notes

PARADYNE - PROPRIETARY

THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF PARADYNE CORPORATION AND IS NOT TO BE DISCLOSED OR USED EXCEPT IN ACCORDANCE WITH APPLICABLE AGREEMENTS.

Unpublished and Not for Publication

All Rights Reserved


Release Number: 04.01.11 Date: April 5, 2001
Release Type: Major Country Type: All
Release History
Affected Product Models
Release
Type
Date
Model
Description
04.01.11
Major
4/5/01
6350-A1/A2
Initial Release 

  1. Feature Enhancements / Functional Changes

  2.  

     

    • This is the initial release for ReachDSL
     
     

  3. Resolved Customer Issues
  4. Action Request Number
    Description
    N/A
     
  5. Hardware Co-Requirements

  6.  

     

    For proper operation with an 88xx/86xx DSLAM, this release requires an 8000 IP Conservative MCC, MCC Plus, or MCP with appropriate firmware:
     
    Card Type CCA # DSLAM
    8312 MVL 12 Port Card 868-3426-8201, Rev .80A 8610 and 8820
    8314 MVL 12 Port Card 868-4427-8000, Rev 80A 8820, 8620
    8000 IP Conservative MCC 868-1010-81xx (xx = 00, 01, 02, …) 8600, 8800, 8810
    8000 IP Conservative MCC Plus 868-3882-80xx (xx = 00, 01, 02, …) 8600, 8800, 8810
    8000 IP Conservative MCP 868-3883-80xx (xx = 00, 01, 02, …) 8610 and 8820, 8620
    6350-A1 ReachDSL RTU 868-1247-8100 N/A
    6350-A1 ReachDSL RTU (International) 868-3432-8000 N/A
    6350-A2 ReachDSL RTU 868-3527-8001 N/A

  7. Software Co-Requirements
  8. Card Type CCA # Firmware
    8312 MVL 12 Port Card 868-3426-8201, Rev .80A 04.01.17 or greater
    8314 MVL 12 Port Card 868-4427-8000, Rev 80A 04.01.17 or greater
  9. Compatibility With Other Released Models
• 6310-A1 RTUs should not be used in a multi-point configuration on 8312 MVL line cards.

• 6310-A2 and 6310-A3 RTUs can be used in a multi-point configuration and can be mixed, ie. , user can utilize -A2s and -A3s multi-dropped on the same port.

• If loop length is greater that 8k better performance is achieved if there is at least one -A3 endpoint in the configuration.

** Note: ReachDSL (6350-Ax-xxx) end points should not be used in a multi-point configuration.
 

        5a.  Upgrading Procedures
This firmware is to be used when upgrading a 6350-A1, A2 ReachDSL End Point.  Once you upgrade an MVL (6310-A1, A2) End Point to ReachDSL (6350-A1, A2), the model number changes to 6350 and the End Point can't be down rev. back to MVL.  Any subsequent upgrades should be using the 6350 file. To check the model number for the End Point, go to the SN information screen (B-E) on the Line Card.  This only applies to End Points.  Line Cards can be down rev. back to MVL.  The following matrix displays the different file types.
 
 
Model Number Firmware File Ethernet Download Program
6310-A1/A2-xxx 6310a1_a2_xxxxxx.bin Pxxxxxx.exe
6310-A3-xxx 6310a3_xxxxxx.bin Pxxxxxx.exe
6350-A1/A2-xxx 6350a1_a2_xxxxxx.bin Dxxxxxx.exe