Paradyne Firmware/Software/Hardware Release Notes

PARADYNE - PROPRIETARY

THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF PARADYNE CORPORATION AND IS NOT TO BE DISCLOSED OR USED EXCEPT IN ACCORDANCE WITH APPLICABLE AGREEMENTS.

Unpublished and Not for Publication

All Rights Reserved

Release Number: V02.03.23 Date: 03/13/2002
Release Type: Minor Country Type: N/A
Release History Affected Product Models: 7975-A2 
Release
Type
Date
Model
Description
V02.03.23 Minor 03/13/02 7975-A2 Maintenance Release
V02.03.12 Major 01/07/02 7975-A2 Globespan code release A.104 to support new E1<->Nx64 payload rates
V01.00.18
 Initial
03/12/01
7975-A2 Initial Release

1. Feature Enhancements / Functional Changes:

M/SDSL endpoint with that supports subrates below 400 (144 kbps, 272 kbps), dual voltage power supply ( +24 volt, -48 volt), alarm contact population option, Tx Power attenuation strap.  This release includes enhanced SNMP device management.

Note: When upgrading code from an earlier version to V01.01.00 or higher through tftp, the user will need to use the ocd file. Once this release is active, the TFTP
will only allow FPI files to be uploaded/downloaded. The OCD file is still used for minimum download.
 

2. Resolved Customer Issues:

     
    Action Request Number
    Description
    PDNaa00320
     Disable Send All Ones on Data Port

    A customer request that the firmware detect that an X21 interface cable is attached to the DTE and automaticaly change the "SENDALL ONES ON DATA PORT NOT READY"  strap TO DISABLED, (because it is invalid for X.21 interface type). If the interface type is X.21, the f/w filters "Send All Ones on Data Port Not Ready" option and set Send All Ones to Disabled.

    Recommend upgrade if your interfacing to an X21 interface.

    PDNaa05592 Problem with Loopback

    On the 7975-A2 the Network Line loopback and Data Channel Loopback, do 
    not work unless the SYNC port is attached to a DTE device. Example:
    Fireberd----8779----7975---(no equipment attached to the DTE)

    Recommend firmware upgrade.

3. Hardware Co-Requirements:

None.

4. Software Co-Requirements:
 
Card Type Firmware
8777 T1 TDM-SDSL 8 port line card A01.02.04 or later
8779 E1 TDM-SDSL 8 port line card A01.02.04 or later
8774 T1 TDM-SDSL 4 port line card 06.00.00 or later
8775 TDM-SDSL 4 port line card 06.00.00 or later
8776 E1 TDM-SDSL 4 port line card 06.00.00 or later
Endpoint Type Firmware
7974-A1 T1 TDM-SDSL  06.00.00 or later
7974-A2 T1 TDM-SDSL  N01.00.18 or later
7975-A1 EIA-530 TDM-SDSL  06.00.00 or later
7975-A2 EIA-530 TDM-SDSL  V01.00.18 or later
7976-A1 E1 TDM-SDSL  06.00.00 or later
7976-A2 E1 TDM-SDSL  N01.00.18 or later

DSP Code: This release includes Globespan M/SDSL release 0A.104

Note: When 7975 is NTU with 8779 LTU, use 8779 build A01.01.00 or later for 528kbps, 144kbps rates to run properly.

5. Compatibility With Other  Releases:

For customer payload data, this release is fully compatible with all previously released models.

511 Pattern Test is not supported in this release.

Compatibility with First Generation products (797x-A1, 8774, 8775, 8776):

Compatibility with Second Generation products (797x-A2, 8779, 8777):


6. Supporting Customer Documentation / Significant Changes:

The following updated manuals support this product: