-- -- This file contains the following MIB definitions: -- -- 6700-NMS-MIB Release 2.0.0 ** PROPOSED ** -- 6700-DEV-MIB Release 2.0.0 ** PROPOSED ** -- 6700-TRAPS Release 2.0.0 ** PROPOSED ** -- 6700-NMS-MIB DEFINITIONS ::= BEGIN -- Title: COMSPHERE 6700 NMS MIB for Customer Network Management -- Release: 2.0.0 (3/3/97) ** PROPOSED ** -- -- Copyright (C) 1994-1997, Paradyne Corp. All rights reserved. -- -- This file may be freely copied and distributed as -- long as no changes are made to it. -- The NMS MIB contains attributes of the 6700 NMS entity. -- The user can inspect and control the 6700 NMS via this MIB. IMPORTS IpAddress FROM RFC1155-SMI DisplayString FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212 DateAndTime FROM HOST-RESOURCES-MIB nms-6700 FROM ATTDCE-MIB; -- -- Enterprise Identification for COMSPHERE 6700 NMS MIB -- nms OBJECT IDENTIFIER ::= { nms-6700 1 } -- NMS MIB -- -- NMS MIB Groups -- nmsAdmin OBJECT IDENTIFIER ::= { nms 1 } -- administration nmsSystem OBJECT IDENTIFIER ::= { nms 2 } -- system identity nmsDevice OBJECT IDENTIFIER ::= { nms 3 } -- 6700 devices nmsManager OBJECT IDENTIFIER ::= { nms 4 } -- SNMP managers nmsTest OBJECT IDENTIFIER ::= { nms 5 } -- tests nmsTransaction OBJECT IDENTIFIER ::= { nms 6 } -- transactions nmsReport OBJECT IDENTIFIER ::= { nms 7 } -- reports nmsAlarm OBJECT IDENTIFIER ::= { nms 8 } -- alarm config nmsError OBJECT IDENTIFIER ::= { nms 9 } -- SNMP error inf nmsTemp OBJECT IDENTIFIER ::= { nms 10 } -- temp regs -- NMS Administration Group (nms 1) -- NMS Information nmsAdminName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..15)) ACCESS read-write STATUS mandatory DESCRIPTION "Name of the 6700 NMS." ::= { nmsAdmin 1 } nmsAdminLocation OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) ACCESS read-write STATUS mandatory DESCRIPTION "Location of the 6700 NMS." ::= { nmsAdmin 2 } nmsAdminContact1 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) ACCESS read-write STATUS mandatory DESCRIPTION "Contact 1 for the 6700 NMS." ::= { nmsAdmin 3 } nmsAdminContact2 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) ACCESS read-write STATUS mandatory DESCRIPTION "Contact 2 for the 6700 NMS." ::= { nmsAdmin 4 } -- NMS Community Names nmsAdminNmsReadCommunity OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "NMS read community name. This community has read-only access to all objects in the COMSPHERE 6700 NMS MIB. An exception applies with the nmsAdminNmsWriteCommunity object, for which the read community provides no access." ::= { nmsAdmin 5 } nmsAdminNmsWriteCommunity OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "NMS write community name. This community provides full access to all objects in the COMSPHERE 6700 NMS MIB." ::= { nmsAdmin 6 } -- Device Community Names nmsAdminBaseReadCommunity OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) ACCESS read-only STATUS mandatory DESCRIPTION "Base read community name string used with Device MIB. When string length is zero, the device read community name is equal to the device name." ::= { nmsAdmin 7 } nmsAdminBaseWriteCommunity OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) ACCESS read-only STATUS mandatory DESCRIPTION "Base write community name string used with Device MIB. When string length is zero, the device write community name is equal to the device name." ::= { nmsAdmin 8 } -- Manager IP Address Checking (Rel 2.0) nmsAdminIpSecurity OBJECT-TYPE SYNTAX INTEGER { knownManagers(1), anyManagers(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to knownManagers(1) to enable IP address checking (this is the default). Set to anyManagers(2) to disable IP address checking for all manager requests." ::= { nmsAdmin 9 } -- NMS System Group (nms 2) -- Time of Day nmsSystemTime OBJECT-TYPE SYNTAX DateAndTime ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the date and time in RFC 1514 DateAndTime format. The date and time are obtained from the system clock of the workstation running the proxy agent software." ::= { nmsSystem 1 } -- Features nmsSystemFeatures OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of COMSPHERE 6700 NMS product or feature entries in nmsSystemFeatureTable." ::= { nmsSystem 2 } nmsSystemFeatureTable OBJECT-TYPE SYNTAX SEQUENCE OF NmsSystemFeatureEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The nms feature table contains a list of software products/features installed in the COMSPHERE 6700 NMS." ::= { nmsSystem 3 } nmsSystemFeatureEntry OBJECT-TYPE SYNTAX NmsSystemFeatureEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the software feature table." INDEX { nmsSystemFeatureIndex } ::= { nmsSystemFeatureTable 1 } -- Layout of one entry in nmsSystemFeatureTable. NmsSystemFeatureEntry ::= SEQUENCE { nmsSystemFeatureIndex INTEGER, nmsSystemFeatureName DisplayString, nmsSystemFeatureVersion DisplayString, nmsSystemFeatureSerial DisplayString } -- Index nmsSystemFeatureIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of the entry." ::= { nmsSystemFeatureEntry 1 } -- Name nmsSystemFeatureName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..25)) ACCESS read-only STATUS mandatory DESCRIPTION "Name of system product or feature." ::= { nmsSystemFeatureEntry 2 } -- Version nmsSystemFeatureVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..25)) ACCESS read-only STATUS mandatory DESCRIPTION "Version of system product or feature." ::= { nmsSystemFeatureEntry 3 } -- Serial Number nmsSystemFeatureSerial OBJECT-TYPE SYNTAX DisplayString (SIZE (0..25)) ACCESS read-only STATUS mandatory DESCRIPTION "Serial number of system product or feature. If feature has no serial number, this object contains a zero length string." ::= { nmsSystemFeatureEntry 4 } -- Low Disk Space Monitor and Alarm Parameters (Rel 2.0) nmsSystemDiskSpace OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of megabytes free disk space on the file system volume where the 6700 NMS is installed. Note that the 6700 NMS cannot operate with under 5 megabytes of free disk space." ::= { nmsSystem 4 } nmsSystemDiskSpaceAlarmThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Number of megabytes free disk space at which low disk space alarm threshold is set. The installation default value is 10 megabytes. Values less than 10 are not accepted." ::= { nmsSystem 5 } nmsSystemDiskSpaceClearThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Number of megabytes free disk space at which low disk space alarm clears. The installation default value is 15 megabytes. Values less than 11 are not accepted" ::= { nmsSystem 6 } -- NMS Device Group (nms 3) nmsDevices OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of devices configured in the 6700 nms network. This is also the number of entries in nmsDeviceTable." ::= { nmsDevice 1 } nmsDeviceTable OBJECT-TYPE SYNTAX SEQUENCE OF NmsDeviceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The nms device table contains an alpha-sorted list of names of devices configured for management in the COMSPHERE 6700 NMS." ::= { nmsDevice 2 } nmsDeviceEntry OBJECT-TYPE SYNTAX NmsDeviceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the nms device table." INDEX { nmsDeviceIndex } ::= { nmsDeviceTable 1 } -- Layout of one entry in nmsDeviceTable. NmsDeviceEntry ::= SEQUENCE { nmsDeviceIndex INTEGER, nmsDeviceName DisplayString, nmsDeviceHuntGroup DisplayString } nmsDeviceIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object is the row index of the nmsDevice table. Note that a device's index in the table may change as devices are added or removed from the 6700 nms network, thus this index should not be used as a device ID." ::= { nmsDeviceEntry 1 } nmsDeviceName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..19)) ACCESS read-only STATUS mandatory DESCRIPTION "This object is the device name, as assigned within the COMSPHERE 6700 NMS. If the device has a dial backup module, an additional entry appears for the dial backup module, formatted as the device name with '.dbm' suffix." ::= { nmsDeviceEntry 2 } -- Hunt Group Name (Rel 2.0 - for remainder of MIB group) nmsDeviceHuntGroup OBJECT-TYPE SYNTAX DisplayString (SIZE (0..15)) ACCESS read-only STATUS mandatory DESCRIPTION "This object is the hunt group name, if any, as assigned within the COMSPHERE 6700 NMS." ::= { nmsDeviceEntry 3 } nmsHuntGroups OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of hunt groups configured in the 6700 nms network. This is also the number of entries in nmsDeviceHuntGroupTable." ::= { nmsDevice 3 } nmsDeviceHuntGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF NmsDeviceHuntGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The nms device hunt group table contains an alpha-sorted list of names of hunt groups configured for management in the COMSPHERE 6700 NMS." ::= { nmsDevice 4 } nmsDeviceHuntGroupEntry OBJECT-TYPE SYNTAX NmsDeviceHuntGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the nms device hunt group table." INDEX { nmsDeviceHuntGroupIndex } ::= { nmsDeviceHuntGroupTable 1 } -- Layout of one entry in nmsDeviceHuntGroupTable. NmsDeviceHuntGroupEntry ::= SEQUENCE { nmsDeviceHuntGroupIndex INTEGER, nmsDeviceHuntGroupName DisplayString } nmsDeviceHuntGroupIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object is the row index of the nmsDeviceHuntGroup table. Note that a hunt group's index in the table may change as hunt groups are added or removed from the 6700 nms network, thus this index should not be used as a hunt group ID." ::= { nmsDeviceHuntGroupEntry 1 } nmsDeviceHuntGroupName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..15)) ACCESS read-only STATUS mandatory DESCRIPTION "This object is the hunt group name." ::= { nmsDeviceHuntGroupEntry 2 } -- NMS Manager Group (nms 4) -- Number of Authorized SNMP Managers nmsManagers OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object contains the number of entries in nmsManagerTable." ::= { nmsManager 1 } -- SNMP Manager Table nmsManagerTable OBJECT-TYPE SYNTAX SEQUENCE OF NmsManagerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The manager table contains a list of SNMP managers authorized access to the COMSPHERE 6700 MIBs." ::= { nmsManager 2 } nmsManagerEntry OBJECT-TYPE SYNTAX NmsManagerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the manager table. Entries are indexed by IP Address." INDEX { nmsManagerAddress } ::= { nmsManagerTable 1 } -- Layout of one entry in nmsManagerTable. NmsManagerEntry ::= SEQUENCE { nmsManagerAddress IpAddress, nmsManagerName DisplayString, nmsManagerAccess INTEGER, nmsManagerTraps INTEGER, nmsManagerLocation DisplayString, nmsManagerContact1 DisplayString, nmsManagerContact2 DisplayString, nmsManagerEntryStatus INTEGER } -- Table Index (Manager IP Address) nmsManagerAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "This object is the row index in the manager table." ::= { nmsManagerEntry 1 } -- Manager Name nmsManagerName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..16)) ACCESS read-write STATUS mandatory DESCRIPTION "This object is the NMS manager name. The manager name must be unique in the table. If a set operation is performed for a non-existing instance (i.e., index is a new IP address), a new table entry for the specified IP address will be created. The new entry's nmsManagerAccess will be defaulted to read-only(2), the nmsManagerTraps to disabled(2), the nmsManagerLocation, nmsManagerContact1, and nmsManagerContact2 to zero length octet strings, and nmsManagerStatus to valid(1)." ::= { nmsManagerEntry 2 } -- Access nmsManagerAccess OBJECT-TYPE SYNTAX INTEGER { no-access(1), read-only-access(2), read-write-access(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Maximum manager access level setting can be none(1), read-only(2), or read-write(3)." ::= { nmsManagerEntry 3 } -- Traps nmsManagerTraps OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies if trap forwarding is enabled for this manager." ::= { nmsManagerEntry 4 } -- Location nmsManagerLocation OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) ACCESS read-write STATUS mandatory DESCRIPTION "Text string describing manager location." ::= { nmsManagerEntry 5 } -- Contact1 nmsManagerContact1 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) ACCESS read-write STATUS mandatory DESCRIPTION "Text string describing manager contact 1." ::= { nmsManagerEntry 6 } -- Contact2 nmsManagerContact2 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) ACCESS read-write STATUS mandatory DESCRIPTION "Text string describing manager contact 2." ::= { nmsManagerEntry 7 } -- Entry Status (Used to Delete an Entry) nmsManagerEntryStatus OBJECT-TYPE SYNTAX INTEGER { valid(1), invalid(2) -- deletes entry from table } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to delete an entry from the table. Only the invalid(2) value is allowed on write." ::= { nmsManagerEntry 8 } -- NMS Test Group (nms 5) -- Textual Convention for Test Result Validity Indicator TestResultValidity ::= INTEGER { valid-final(1), valid-intermediate(2), not-available-yet(3), count-overflow(4), not-used(5) } -- Number of Test Table Entries nmsTestEntries OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of NMS Test table entries that are configured. This number is controlled by the following lines in the 6700 profile (default value is shown). [SNMP] NmsTestEntries=8" ::= { nmsTest 1 } -- Test Table nmsTestTable OBJECT-TYPE SYNTAX SEQUENCE OF NmsTestEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The NMS Test table uses RMON-style arbitration (RFC 1271) to allocate device test slots. There are 8 (by default) simultaneous test slots available. Each test slot controls testing of a single device (or a control-tributary pair, depending on the test type)." ::= { nmsTest 2 } nmsTestEntry OBJECT-TYPE SYNTAX NmsTestEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the nms test table." INDEX { nmsTestIndex } ::= { nmsTestTable 1 } -- Layout of one entry in nmsTestTable. NmsTestEntry ::= SEQUENCE { nmsTestIndex INTEGER, nmsTestDeviceName DisplayString, nmsTestType INTEGER, nmsTestDuration INTEGER, nmsTestPortNumber INTEGER, nmsTestRemoteName DisplayString, nmsTestStatus INTEGER, nmsTestLocalTotalSecondsValidity TestResultValidity, nmsTestLocalTotalSeconds INTEGER, nmsTestLocalErrorSecondsValidity TestResultValidity, nmsTestLocalErrorSeconds INTEGER, nmsTestLocalTotalBlocksValidity TestResultValidity, nmsTestLocalTotalBlocks INTEGER, nmsTestLocalErrorBlocksValidity TestResultValidity, nmsTestLocalErrorBlocks INTEGER, nmsTestRemoteTotalSecondsValidity TestResultValidity, nmsTestRemoteTotalSeconds INTEGER, nmsTestRemoteErrorSecondsValidity TestResultValidity, nmsTestRemoteErrorSeconds INTEGER, nmsTestRemoteTotalBlocksValidity TestResultValidity, nmsTestRemoteTotalBlocks INTEGER, nmsTestRemoteErrorBlocksValidity TestResultValidity, nmsTestRemoteErrorBlocks INTEGER, nmsTestTimeOutsValidity TestResultValidity, nmsTestTimeOuts INTEGER, nmsTestOwner DisplayString, nmsTestEntryStatus INTEGER, nmsTestNotify INTEGER, nmsTestErrorDesc DisplayString } -- Index nmsTestIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object is the test table entry index." ::= { nmsTestEntry 1 } -- -- Device Name -- nmsTestDeviceName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..15)) ACCESS read-write STATUS mandatory DESCRIPTION "The name of the device to test." ::= { nmsTestEntry 2 } -- -- Test Type -- nmsTestType OBJECT-TYPE SYNTAX INTEGER { self-test(1), local-loop(2), rem-digital-loop(3), loc-digital-loop(4), dte-loop(5), bert(6), local-loop-bert(7), rdl-bert(8), digital-test(9), end-to-end-test(10), abort(11) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is the test type. Test type self-test(1) performs an internal self-test of the device. Test type local-loop(2) places the device into local loopback (for modems, this is a CCITT V.54 Loop 3). Test type rem-digital-loop(3) places the device in a remote digital loopback (for modems, this is a CCITT V.54 Loop 2). Test type loc-digital-loop(4) forces a local device to loopback any data received from the remote device (this is useful if the remote device is incapable of initiating a remote digital loopback from its location). Test type dte-loop(5) loops a DSU's data port back to the DTE/DCE interface on a per-port basis without affecting the operation of the remaining ports. Test type bert(6) initiates a pattern test. Test type local-loop-bert(7) places the device into local loopback and initiates a pattern test. Test type rdl-bert(8) places the device into remote digital loopback and initiates a pattern test. Test type digital-test(9) initiates a digital test of a pair of DSUs or DBMs and the data circuit between them. Test type end-to-end-test(10) initiates an end to end test of two devices. Test type abort aborts the current test." ::= { nmsTestEntry 3 } -- -- Test Duration -- nmsTestDuration OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Test duration in seconds (or blocks). Only applicable for the following test types: bert, local-loop-bert, rdl-bert, digital-test, end-to-end-test." ::= { nmsTestEntry 4 } -- -- Port Number -- nmsTestPortNumber OBJECT-TYPE SYNTAX INTEGER { aggregate(1), port1(2), port2(3), port3(4), port4(5), port5(6), port6(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Port number. Only applicable for multi-port devices. Also only applicable for the following test types: rem-digital-loop, loc-digital-loop, dte-loop, bert, local-loop-bert, rdl-bert, digital-test, end-to-end-test." ::= { nmsTestEntry 5 } -- -- Remote Device Name -- nmsTestRemoteName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..15)) ACCESS read-write STATUS mandatory DESCRIPTION "Remote device name. Only applicable for the following test types: digital-test, end-to-end-test." ::= { nmsTestEntry 6 } -- -- Test Status -- nmsTestStatus OBJECT-TYPE SYNTAX INTEGER { idle(1), testMode(2), testRunning(3), testAborted(4), testFailed(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Test status. Status of idle(1) indicates that the device is not in test mode (from this control point); this is the initial value after createRequest. Status of testMode(2) indicates that the device is in a test mode (such as loopback); no further test results are pending. Status of testRunning(3) means the device is in test mode (such as bert test) and test results are pending. Status of testAborted(4) indicates that the device test was aborted and the device is no longer in test mode. Status of testFailed(5) indicates that the test has failed. Reason for test failure may be: invalid test parameter; device locked by another user; conflict with device environment, features, or configuration; device failure." ::= { nmsTestEntry 7 } -- Test Results -- Local Total Seconds nmsTestLocalTotalSecondsValidity OBJECT-TYPE SYNTAX TestResultValidity ACCESS read-only STATUS mandatory DESCRIPTION "Validity of the nmsTestLocalTotalSeconds test result object." ::= { nmsTestEntry 8 } nmsTestLocalTotalSeconds OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total seconds for local device. (For 3600 model type devices, this variable is also called elapsed seconds.)" ::= { nmsTestEntry 9 } -- Local Error Seconds nmsTestLocalErrorSecondsValidity OBJECT-TYPE SYNTAX TestResultValidity ACCESS read-only STATUS mandatory DESCRIPTION "Validity of the nmsTestLocalErrorSeconds test result object." ::= { nmsTestEntry 10 } nmsTestLocalErrorSeconds OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Errored seconds elapsed for local device. (The value is not used for 3600 model type devices.)" ::= { nmsTestEntry 11 } -- Local Total Blocks (Bits for 3600 DSU) nmsTestLocalTotalBlocksValidity OBJECT-TYPE SYNTAX TestResultValidity ACCESS read-only STATUS mandatory DESCRIPTION "Validity of the nmsTestLocalTotalBlocks test result object." ::= { nmsTestEntry 12 } nmsTestLocalTotalBlocks OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total blocks for local device." ::= { nmsTestEntry 13 } -- Local Error Blocks (Bits for 3600 DSU) nmsTestLocalErrorBlocksValidity OBJECT-TYPE SYNTAX TestResultValidity ACCESS read-only STATUS mandatory DESCRIPTION "Validity of the nmsTestLocalErrorBlocks test result object." ::= { nmsTestEntry 14 } nmsTestLocalErrorBlocks OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Error Blocks for 3800 and 3900 modems, or Local Error Blocks (actually Bits) for 3600 DSUs; " ::= { nmsTestEntry 15 } -- Remote Total Seconds nmsTestRemoteTotalSecondsValidity OBJECT-TYPE SYNTAX TestResultValidity ACCESS read-only STATUS mandatory DESCRIPTION "Validity of the nmsTestRemoteTotalSeconds test result object." ::= { nmsTestEntry 16 } nmsTestRemoteTotalSeconds OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total seconds for remote device. (For 3600 model type devices, this variable is also called elapsed seconds.)" ::= { nmsTestEntry 17 } -- Remote Error Seconds nmsTestRemoteErrorSecondsValidity OBJECT-TYPE SYNTAX TestResultValidity ACCESS read-only STATUS mandatory DESCRIPTION "Validity of the nmsTestRemoteErrorSeconds test result object." ::= { nmsTestEntry 18 } nmsTestRemoteErrorSeconds OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Errored seconds elapsed for the remote device. (The value is not used for 3600 model type devices.)" ::= { nmsTestEntry 19 } -- Remote Total Blocks (Bits for 3600 DSU) nmsTestRemoteTotalBlocksValidity OBJECT-TYPE SYNTAX TestResultValidity ACCESS read-only STATUS mandatory DESCRIPTION "Validity of the nmsTestRemoteTotalBlocks test result object." ::= { nmsTestEntry 20 } nmsTestRemoteTotalBlocks OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total blocks for remote device." ::= { nmsTestEntry 21 } -- Remote Error Blocks (Bits for 3600 DSU) nmsTestRemoteErrorBlocksValidity OBJECT-TYPE SYNTAX TestResultValidity ACCESS read-only STATUS mandatory DESCRIPTION "Validity of the nmsTestRemoteErrorBlocks test result object." ::= { nmsTestEntry 22 } nmsTestRemoteErrorBlocks OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Remote Error blocks (actually Bits). Not used for 3800 and 3900 model type devices.)" ::= { nmsTestEntry 23 } -- Time Outs nmsTestTimeOutsValidity OBJECT-TYPE SYNTAX TestResultValidity ACCESS read-only STATUS mandatory DESCRIPTION "Validity of the nmsTestTimeOuts test result object." ::= { nmsTestEntry 24 } nmsTestTimeOuts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Time outs. Not used for 3800 and 3900 model type devices." ::= { nmsTestEntry 25 } -- Test Owner nmsTestOwner OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "The entity that configured this entry and is therefore using the resources assigned to it. It is suggested that this string contain one or more of the following: IP address, management station name, network manager's name, location, or phone number." ::= { nmsTestEntry 26 } -- Entry Status nmsTestEntryStatus OBJECT-TYPE SYNTAX INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) } ACCESS read-write STATUS mandatory DESCRIPTION "The status of this nmsTestTable entry. Setting this object to the value invalid(4) has the effect of invalidating the corresponding entry. If there is a test active when the entry is invalidated, the test will be aborted. An existing instance of this object cannot be set to createRequest(2). This object may only be set to createRequest(2) when a new test instance is created. Immediately after completing the create operation, the proxy agent will set this object to underCreation(3). Entries shall exist in the underCreation(3) state until the management station is finished configuring the entry and sets this object to valid(1) or aborts, setting this object to invalid(4). If the proxy agent determines that an entry has been in the underCreation(3) state for an abnormally long time, it may decide that the management station has crashed. If the proxy agent makes this decision, it will set the object to invalid(4)." ::= { nmsTestEntry 27 } -- Test Notification (Rel 2.0) nmsTestNotify OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "If enabled, a Test Completed trap is generated when the testing has finished. Default is disabled(1)." ::= { nmsTestEntry 28 } -- Error Description (Rel 2.0) nmsTestErrorDesc OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Error message from last test, or null string if no error." ::= { nmsTestEntry 29 } -- NMS Transaction Group (nms 6) (Rel 2.0) -- Number of Transaction Table Entries nmsTransactionEntries OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of NMS Transaction table entries configured. This number is controlled by the following lines in the 6700 profile (default value is shown). [SNMP] NmsTransactionEntries=8" ::= { nmsTransaction 1 } -- Transaction Table nmsTransactionTable OBJECT-TYPE SYNTAX SEQUENCE OF NmsTransactionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The NMS Transaction table uses RMON-style arbitration (RFC 1271) to allocate transaction sessions. There are 8 (by default) simultaneous transaction slots available. Each transaction slot allows for a single outstanding transaction command." ::= { nmsTransaction 2 } nmsTransactionEntry OBJECT-TYPE SYNTAX NmsTransactionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the nms Transaction table." INDEX { nmsTransactionIndex } ::= { nmsTransactionTable 1 } -- Layout of one entry in nmsTransactionTable. NmsTransactionEntry ::= SEQUENCE { nmsTransactionIndex INTEGER, nmsTransactionEntryStatus INTEGER, nmsTransactionCommandString DisplayString, nmsTransactionResponseString DisplayString, nmsTransactionStatus INTEGER, nmsTransactionOwner DisplayString, nmsTransactionOwnerIpAddr IpAddress, nmsTransactionNotify INTEGER } -- Index nmsTransactionIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object is the Transaction table entry index." ::= { nmsTransactionEntry 1 } -- Entry Status nmsTransactionEntryStatus OBJECT-TYPE SYNTAX INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) } ACCESS read-write STATUS mandatory DESCRIPTION "The status of this nmsTransactionTable entry and its allocated workspace. Setting this object to the value invalid(4) has the effect of invalidating the corresponding entry. If there is a transaction active when the entry is invalidated, the transaction results are undefined. An existing instance of this object cannot be set to createRequest(2). This object may only be set to createRequest(2) when creating a new transaction instance. Immediately after completing the create operation, the proxy agent will set this object to underCreation(3). Entries shall exist in the underCreation(3) state until the management station is finished configuring the entry and sets this object to valid(1) or aborts, setting this object to invalid(4). If the proxy agent determines that an entry has been in the underCreation(3) state for an abnormally long time, it may decide that the management station has crashed. If the proxy agent makes this decision, it will set the object to invalid(4). After transition to valid(1), if the value of the nmsTransactionCommandString is not null, an attempt is made to execute the command string." ::= { nmsTransactionEntry 2 } -- Command nmsTransactionCommandString OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "The transaction command string is entered into this object. When the nmsTransactionEntryStatus is valid, and the nmsTransactionStatus is not busy, a write to this object initiates execution of the command string in the allocated workspace, clearing result information from any previous command. Refer to COMSPHERE 6700 NMS SNMP Proxy Agent Transaction Command Reference for commands and syntax." ::= { nmsTransactionEntry 3 } -- Response nmsTransactionResponseString OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Upon transaction completion, contains the command response." ::= { nmsTransactionEntry 4 } -- Status nmsTransactionStatus OBJECT-TYPE SYNTAX INTEGER { idle(1), busy(2), responseDone(3), responseFail(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of the transaction. Initially the value is idle(1). When a transaction is made active, the value changes to busy(2). Upon transaction completion, the value is responseDone(3) for success or responseFail(4) for command failure." ::= { nmsTransactionEntry 5 } -- Owner nmsTransactionOwner OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "The entity that configured this entry and is therefore using the resources assigned to it. It is suggested that this string contain one or more of the following: IP address, management station name, network manager's name, location, or phone number." ::= { nmsTransactionEntry 6 } -- Owner IP Address nmsTransactionOwnerIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The IP address of the entity that configured this entry." ::= { nmsTransactionEntry 7 } -- Notification nmsTransactionNotify OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "If enabled, a Transaction Completed trap is generated when the transaction has finished. Default is disabled(1)." ::= { nmsTransactionEntry 8 } -- Transaction Response Table nmsTransactionResponseTable OBJECT-TYPE SYNTAX SEQUENCE OF NmsTransactionResponseEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The response table contains a list of response lines to the RANGE transaction command." ::= { nmsTransaction 3 } nmsTransactionResponseEntry OBJECT-TYPE SYNTAX NmsTransactionResponseEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the transaction response table. Entries are indexed by transaction index and by response index." INDEX { nmsTransactionEntryIndex, nmsTransactionResponseIndex } ::= { nmsTransactionResponseTable 1 } -- Layout of one entry in nmsTransactionResponseTable. NmsTransactionResponseEntry ::= SEQUENCE { nmsTransactionEntryIndex INTEGER, nmsTransactionResponseIndex INTEGER, nmsTransactionResponseLine DisplayString } -- Table Index1 (Transaction Entry Index) nmsTransactionEntryIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This the same index used in nmsTransactionIndex." ::= { nmsTransactionResponseEntry 1 } -- Table Index2 (Transaction Response Index) nmsTransactionResponseIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Response line number, starting with 1." ::= { nmsTransactionResponseEntry 2 } -- Response Line nmsTransactionResponseLine OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This object is a transaction command response string from the nmsTransactionResponseEntry Array." ::= { nmsTransactionResponseEntry 3 } -- NMS Report Group (nms 7) (Rel 2.0) nmsReportExpirationDays OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of days before a NMS Report file is automatically deleted. Default is 30 days. Setting the value to zero disables the automatic file deletion feature." ::= { nmsReport 1 } -- Number of Report Table Entries nmsReportEntries OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of NMS Report table entries configured. This number is controlled by the following lines in the 6700 profile (default value is shown). [SNMP] NmsReportEntries=8" ::= { nmsReport 2 } -- Report Table nmsReportTable OBJECT-TYPE SYNTAX SEQUENCE OF NmsReportEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The NMS Report table uses RMON-style arbitration (RFC 1271) to allocate Report sessions. There are 8 (by default) simultaneous report slots available. Each report slot allows for a single outstanding report operation." ::= { nmsReport 3 } nmsReportEntry OBJECT-TYPE SYNTAX NmsReportEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the nms Report table." INDEX { nmsReportIndex } ::= { nmsReportTable 1 } -- Layout of one entry in nmsReportTable. NmsReportEntry ::= SEQUENCE { nmsReportIndex INTEGER, nmsReportEntryStatus INTEGER, nmsReportType INTEGER, nmsReportName DisplayString, nmsReportScope DisplayString, nmsReportStart DateAndTime, nmsReportStop DateAndTime, nmsReportStatus INTEGER, nmsReportErrorDesc DisplayString, nmsReportOwner DisplayString, nmsReportOwnerIpAddr IpAddress, nmsReportNotify INTEGER } -- Index nmsReportIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object is the Report table entry index." ::= { nmsReportEntry 1 } nmsReportEntryStatus OBJECT-TYPE SYNTAX INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) } ACCESS read-write STATUS mandatory DESCRIPTION "The status of this nmsReportTable entry. Setting this object to the value invalid(4) has the effect of invalidating the corresponding entry. If there is a report active when the entry is invalidated, the report will be halted and deleted. An existing instance of this object cannot be set to createRequest(2). This object may only be set to createRequest(2) when creating a new transaction instance. Immediately after completing the create operation, the proxy agent will set this object to underCreation(3). Entries shall exist in the underCreation(3) state until the management station is finished configuring the entry and sets this object to valid(1) or aborts, setting this object to invalid(4). If the proxy agent determines that an entry has been in the underCreation(3) state for an abnormally long time, it may decide that the management station has crashed. If the proxy agent makes this decision, it will set the object to invalid(4)." ::= { nmsReportEntry 2 } nmsReportType OBJECT-TYPE SYNTAX INTEGER { noOp(1), callStatistics(2), callFault(3), deviceList(4), alarmHistory(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The report type is selected via this object. Default value is noOp(1) which produces no report." ::= { nmsReportEntry 3 } nmsReportName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "The name for the report file that is generated. The file name must be appropriate for the operating system hosting the 6700 NMS. The file name may not contain path information; all reports are written to the SNMP\REPORT subdirectory of the 6700 install directory (the installation default is C:\PCNMS\SNMP\REPORT)." ::= { nmsReportEntry 4 } nmsReportScope OBJECT-TYPE SYNTAX DisplayString (SIZE (0..15)) ACCESS read-write STATUS mandatory DESCRIPTION "The scope for the report file that is generated. If a device name is used, then the report is limited to the single device. If a hunt group name is used, then the report covers all devices in the hunt group. If null, all possible devices are reported." ::= { nmsReportEntry 5 } nmsReportStart OBJECT-TYPE SYNTAX DateAndTime ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the report start date and time in RFC 1514 DateAndTime format." ::= { nmsReportEntry 6 } nmsReportStop OBJECT-TYPE SYNTAX DateAndTime ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the report stop date and time in RFC 1514 DateAndTime format." ::= { nmsReportEntry 7 } nmsReportStatus OBJECT-TYPE SYNTAX INTEGER { idle(1), busy(2), reportDone(3), reportFail(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of the report. Initially the value is idle(1). When a report operation is started, the value changes to busy(2). Upon report completion, the value is reportDone(3) for success or reportFail(4) for report failure." ::= { nmsReportEntry 8 } nmsReportErrorDesc OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Error message from last report, or null string if no error." ::= { nmsReportEntry 9 } nmsReportOwner OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "The entity that configured this entry and is therefore using the resources assigned to it. It is suggested that this string contain one or more of the following: IP address, management station name, network manager's name, location, or phone number." ::= { nmsReportEntry 10 } nmsReportOwnerIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The IP address of the entity that configured this entry." ::= { nmsReportEntry 11 } nmsReportNotify OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "If enabled, a Report Completed trap is generated when the transaction has finished. Default is disabled(1)." ::= { nmsReportEntry 12 } -- NMS Alarm Group (nms 8) (Rel 2.0) -- NMS Alarm Table nmsAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF NmsAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Alarm table contains a list of actions, specific to each authorized manager, to be taken when the respective trap condition occurs." ::= { nmsAlarm 1 } nmsAlarmEntry OBJECT-TYPE SYNTAX NmsAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the alarm table. Entries are indexed by recipient IP Address and alarm number." INDEX { nmsAlarmRecipient, nmsAlarmClass, nmsAlarmNumber } ::= { nmsAlarmTable 1 } -- Layout of one entry in nmsAlarmTable. NmsAlarmEntry ::= SEQUENCE { nmsAlarmRecipient IpAddress, nmsAlarmClass INTEGER, nmsAlarmNumber INTEGER, nmsAlarmDisposition INTEGER } -- Table Index1 (Alarm Recipient IP Address) nmsAlarmRecipient OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "This object is the IP address of a manager configured to receive traps from the proxy agent." ::= { nmsAlarmEntry 1 } -- Table Index2 (Device class of Alarm originator) nmsAlarmClass OBJECT-TYPE SYNTAX INTEGER { dial(1), apl(2), dsu(3), nms(99) } ACCESS read-only STATUS mandatory DESCRIPTION "The device class of the alarm originator." ::= { nmsAlarmEntry 2 } -- Table Index3 (Enterprise Specific Trap Number) nmsAlarmNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object is the enterprise specific trap number of an alarm that can be generated by the proxy agent. If alarm number zero is used on a Disposition Set request, then all alarms for the device class are set to the specified disposition." ::= { nmsAlarmEntry 3 } -- Disposition nmsAlarmDisposition OBJECT-TYPE SYNTAX INTEGER { send(1), log(2), sendAndLog(3), ignore(4) } ACCESS read-write STATUS mandatory DESCRIPTION "When set to send(1), the alarm is exported as an enterprise trap. When set to log(2), the alarm is logged in the alarm history log. When set to sendAndLog(3), the alarm is both exported as a trap and logged in the alarm history log. When set to ignore(4), the alarm event is ignored." ::= { nmsAlarmEntry 4 } -- NMS Alarm Profile nmsAlarmProfileTable OBJECT-TYPE SYNTAX SEQUENCE OF NmsAlarmProfileEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Alarm profile table allows management of alarm profiles." ::= { nmsAlarm 2 } nmsAlarmProfileEntry OBJECT-TYPE SYNTAX NmsAlarmProfileEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the alarm profile table. Entries are indexed by recipient manager's IP Address." INDEX { nmsAlarmProfileMgr } ::= { nmsAlarmProfileTable 1 } -- Layout of one entry in nmsAlarmProfileTable. NmsAlarmProfileEntry ::= SEQUENCE { nmsAlarmProfileMgr IpAddress, nmsAlarmProfileAutoLoad DisplayString, nmsAlarmProfileLoad DisplayString, nmsAlarmProfileSave DisplayString } -- Table Index (Alarm Recipient IP Address) nmsAlarmProfileMgr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "This object is the IP address of a manager configured to receive traps from the proxy agent." ::= { nmsAlarmProfileEntry 1 } -- Alarm Profile to AutoLoad at Initialization Time nmsAlarmProfileAutoLoad OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The name of the alarm profile that is to be automatically loaded when the 6700 NMS is initialized. The file must exist in the SNMP\CONFIG subdirectory of the 6700 install directory (the installation default is C:\PCNMS\SNMP\CONFIG). There is a default alarm profile provided with the 6700 NMS named default.afp." ::= { nmsAlarmProfileEntry 2 } -- Load an Alarm Profile nmsAlarmProfileLoad OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The name of the alarm profile that is to be loaded. Writing to this object starts the profile load operation. The file must exist in the SNMP\CONFIG subdirectory of the 6700 install directory (the installation default is C:\PCNMS\SNMP\CONFIG)." ::= { nmsAlarmProfileEntry 3 } -- Save Current Alarm Profile to Disk nmsAlarmProfileSave OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The name for the alarm profile that is to be written. Writing to this object starts the profile save operation. The file name must be appropriate for the operating system hosting the 6700 NMS. The file name may not contain path information; all profiles are written to the SNMP\CONFIG subdirectory of the 6700 install directory (the installation default is C:\PCNMS\SNMP\CONFIG)." ::= { nmsAlarmProfileEntry 4 } -- NMS Error Group (nms 9) (Rel 2.0) -- NMS Error Table nmsErrorTable OBJECT-TYPE SYNTAX SEQUENCE OF NmsErrorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Error table lists the ten most recent SNMP errors for each manager IP address." ::= { nmsError 1 } nmsErrorEntry OBJECT-TYPE SYNTAX NmsErrorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the error table. Entries are indexed by recipient IP Address and request identifier." INDEX { nmsErrorRecipient, nmsErrorRequestID } ::= { nmsErrorTable 1 } -- Layout of one entry in nmsErrorTable. NmsErrorEntry ::= SEQUENCE { nmsErrorRecipient IpAddress, nmsErrorRequestID INTEGER, nmsErrorType INTEGER, nmsErrorDesc DisplayString } -- Table Index1 (Error Recipient IP Address) nmsErrorRecipient OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "This object is the IP address of the manager which received the error." ::= { nmsErrorEntry 1 } -- Table Index2 (Request ID) nmsErrorRequestID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object is the request ID used by the manager for the failed SNMP request." ::= { nmsErrorEntry 2 } -- Error Type nmsErrorType OBJECT-TYPE SYNTAX INTEGER { other(1), notSupported(2), invalidParameter(3), invalidChars(4), stringTooLong(5), valueTooHigh(6), valueTooLow(7), notFound(8), alreadyExists(9), invalidIndex(10), invalidOID(11), invalidState(12), configConflict(13), deviceLocked(14), deviceTimeout(15), deviceFail(16), resourceFail(17), notResourceOwner(18), badCommunity(19), readOnly(20), getNextEOF(21), tooBusy(22) } ACCESS read-only STATUS mandatory DESCRIPTION "Error type. Refer to the nmsErrorDesc object for additional information." ::= { nmsErrorEntry 3 } -- Error Description String nmsErrorDesc OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Error description in US English text." ::= { nmsErrorEntry 4 } -- NMS Temp Group (nms 10) (Rel 2.0) -- Temporary working registers used for trap varbinds nmsTempName1 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..25)) ACCESS read-only STATUS mandatory DESCRIPTION "Device name register, used to identify entity sending the trap. May contain a hunt group name." ::= { nmsTemp 1 } nmsTempName2 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..25)) ACCESS read-only STATUS mandatory DESCRIPTION "Device name alternate register, used to identify a new or second entity associated with the trap." ::= { nmsTemp 2 } nmsTempIdentifier OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Identifier register, used to indicate source of event, typically as a table index." ::= { nmsTemp 3 } nmsTempString OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "String register, used for debug information text bound with debug traps." ::= { nmsTemp 4 } nmsTempSerial OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Trap serial number register, used for trap serialization." ::= { nmsTemp 5 } END 6700-DEV-MIB DEFINITIONS ::= BEGIN -- Title: COMSPHERE 6700 Device MIB for Customer Network Management -- Release: 2.0.0 (3/3/97) ** PROPOSED ** -- -- Copyright (C) 1994-1997, Paradyne Corp. All rights reserved. -- -- This file may be freely copied and distributed as -- long as no changes are made to it. -- The Device MIB contains the common device attributes. -- There is an instance of the Device MIB for each device in -- the 6700 network. Each device is identified by a unique -- community string. SNMP Management applications must use -- the community name to specify the device to access. IMPORTS IpAddress, TimeTicks FROM RFC1155-SMI DisplayString FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212 nms-6700 FROM ATTDCE-MIB; UInteger32 ::= INTEGER -- -- Enterprise Identification for COMSPHERE 6700 Device MIB -- dev OBJECT IDENTIFIER ::= { nms-6700 2 } -- Device MIB -- Device MIB Groups devAdmin OBJECT IDENTIFIER ::= { dev 1 } -- administration devIdentity OBJECT IDENTIFIER ::= { dev 2 } -- device identity devStatus OBJECT IDENTIFIER ::= { dev 3 } -- status devCirQual OBJECT IDENTIFIER ::= { dev 4 } -- circuit quality devEIAStatus OBJECT IDENTIFIER ::= { dev 5 } -- EIA status devExtLeads OBJECT IDENTIFIER ::= { dev 6 } -- external leads devCommand OBJECT IDENTIFIER ::= { dev 7 } -- command -- Device Administration Group (dev 1) devAdminName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..15)) ACCESS read-only STATUS mandatory DESCRIPTION "Device name. This is the name used by the COMSPHERE 6700 NMS to identify the device." ::= { devAdmin 1 } devAdminAdpAddress OBJECT-TYPE SYNTAX DisplayString (SIZE (0..15)) ACCESS read-only STATUS mandatory DESCRIPTION "Address of device in the ADP network (the network used by the COMSPHERE 6700 NMS to access the device)." ::= { devAdmin 2 } devAdminModelType OBJECT-TYPE SYNTAX INTEGER { dial(1), apl(2), dsu(3), dbm(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Device model type is dial(1) for COMSPHERE 3800 dial modems, apl(2) for COMSPHERE 3900 leased line modems, dsu(3) for COMSPHERE 3600 DSUs, and dbm(4) for COMSPHERE 3600 Dial Backup Modules." ::= { devAdmin 3 } devAdminSite OBJECT-TYPE SYNTAX DisplayString (SIZE (0..15)) ACCESS read-only STATUS mandatory DESCRIPTION "Device site name used by COMSPHERE 6700 NMS." ::= { devAdmin 4 } devAdminCabinet OBJECT-TYPE SYNTAX DisplayString (SIZE (0..15)) ACCESS read-only STATUS mandatory DESCRIPTION "Device cabinet name used by COMSPHERE 6700 NMS." ::= { devAdmin 5 } devAdminCarrier OBJECT-TYPE SYNTAX DisplayString (SIZE (0..15)) ACCESS read-only STATUS mandatory DESCRIPTION "Device carrier name used by COMSPHERE 6700 NMS. If the device is a standalone model, this object has zero length." ::= { devAdmin 6 } devAdminCarrierSlot OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Device carrier slot number." ::= { devAdmin 7 } devAdminCircuitName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..25)) ACCESS read-only STATUS mandatory DESCRIPTION "Device circuit name." ::= { devAdmin 8 } devAdminContact1 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..25)) ACCESS read-only STATUS mandatory DESCRIPTION "Device contact string #1." ::= { devAdmin 9 } devAdminContact2 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..25)) ACCESS read-only STATUS mandatory DESCRIPTION "Device contact string #2." ::= { devAdmin 10 } devAdminComment OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) ACCESS read-only STATUS mandatory DESCRIPTION "Device comment string." ::= { devAdmin 11 } devAdminDbmOption OBJECT-TYPE SYNTAX INTEGER { dbm-installed(1), dbm-not-installed(2) } ACCESS read-only STATUS mandatory DESCRIPTION "A value of dbm-installed(1) indicates that a dial backup module option is installed." ::= { devAdmin 12 } devAdminMsdOption OBJECT-TYPE SYNTAX INTEGER { msd-installed(1), msd-not-installed(2) } ACCESS read-only STATUS mandatory DESCRIPTION "A value of msd-installed(1) indicates that a modem sharing device option is installed." ::= { devAdmin 13 } devAdminMcmpOption OBJECT-TYPE SYNTAX INTEGER { mcmp-installed(1), mcmp-not-installed(2) } ACCESS read-only STATUS mandatory DESCRIPTION "A value of mcmp-installed(1) indicates that a multi control multi point option is installed." ::= { devAdmin 14 } devAdminTdmOption OBJECT-TYPE SYNTAX INTEGER { tdm-installed(1), tdm-not-installed(2) } ACCESS read-only STATUS mandatory DESCRIPTION "A value of tdm-installed(1) indicates that a time division multiplexer option is installed." ::= { devAdmin 15 } devAdminModelName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..25)) ACCESS read-only STATUS mandatory DESCRIPTION "Device model name used by COMSPHERE 6700 NMS." ::= { devAdmin 16 } -- Hunt Group Name (Rel 2.0) devAdminHuntGroup OBJECT-TYPE SYNTAX DisplayString (SIZE (0..15)) ACCESS read-only STATUS mandatory DESCRIPTION "Device hunt group name. If not assigned to a hunt group, this object contains an empty string." ::= { devAdmin 17 } -- Device Identity Group (dev 2) devIdentityModel OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) ACCESS read-only STATUS mandatory DESCRIPTION "Model number." ::= { devIdentity 1 } devIdentityLineSpeed OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) ACCESS read-only STATUS mandatory DESCRIPTION "Line speed." ::= { devIdentity 2 } devIdentitySoftwareVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) ACCESS read-only STATUS mandatory DESCRIPTION "Software version." ::= { devIdentity 3 } devIdentitySerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) ACCESS read-only STATUS mandatory DESCRIPTION "Serial number." ::= { devIdentity 4 } devIdentityApplModuleID OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) ACCESS read-only STATUS mandatory DESCRIPTION "APPL module (if applicable, otherwise length is zero)." ::= { devIdentity 5 } devIdentityAccessModuleID OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) ACCESS read-only STATUS mandatory DESCRIPTION "Access module (if applicable, otherwise length is zero)." ::= { devIdentity 6 } devIdentityRestoralOption OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) ACCESS read-only STATUS mandatory DESCRIPTION "Restoral option (if applicable, otherwise length is zero)." ::= { devIdentity 7 } devIdentityConfiguration OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) ACCESS read-only STATUS mandatory DESCRIPTION "Configuration (if applicable, otherwise length is zero)." ::= { devIdentity 8 } devIdentityInternationalStrap OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) ACCESS read-only STATUS mandatory DESCRIPTION "International strap." ::= { devIdentity 9 } devIdentityHwPartNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) ACCESS read-only STATUS mandatory DESCRIPTION "Hardware part number." ::= { devIdentity 10 } devIdentitySwPartNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) ACCESS read-only STATUS mandatory DESCRIPTION "Software part number." ::= { devIdentity 11 } devIdentityOption1 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) ACCESS read-only STATUS mandatory DESCRIPTION "Option 1 (if applicable, otherwise length is zero)." ::= { devIdentity 12 } devIdentityOption2 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) ACCESS read-only STATUS mandatory DESCRIPTION "Option 2 (if applicable, otherwise length is zero)." ::= { devIdentity 13 } devIdentityOption3 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) ACCESS read-only STATUS mandatory DESCRIPTION "Option 3 (if applicable, otherwise length is zero)." ::= { devIdentity 14 } devIdentityOption4 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) ACCESS read-only STATUS mandatory DESCRIPTION "Option 4 (if applicable, otherwise length is zero)." ::= { devIdentity 15 } devIdentityOption5 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) ACCESS read-only STATUS mandatory DESCRIPTION "Option 5 (if applicable, otherwise length is zero)." ::= { devIdentity 16 } devIdentityOption6 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) ACCESS read-only STATUS mandatory DESCRIPTION "Option 6 (if applicable, otherwise length is zero)." ::= { devIdentity 17 } -- Device Status Group (dev 3) devStatusConnectedDevice OBJECT-TYPE SYNTAX DisplayString (SIZE (0..15)) ACCESS read-only STATUS mandatory DESCRIPTION "The device name of the connected device. A zero length string will be returned if the information is unavailable." ::= { devStatus 1 } devStatusConnectTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Connect time (in hundredths of seconds)." ::= { devStatus 2 } devStatusAlert OBJECT-TYPE SYNTAX UInteger32 ACCESS read-only STATUS mandatory DESCRIPTION "The current alerts for the device. The bit position number starting with 0 and counting from the right (low order) bit will indicate each active Primary Alert. The Primary Alerts and their bit positions are defined as follows: device-fail(0), config-change-notify(1), test-mode(2), disabled(3), out-of-threshold(4), facility-alarm(5), external-alarm(6), streaming-terminal(7), access-security(8), dial-backup-active(9), dte-alarm(10), subnormal-speed(11), primary-channel-interrupt(12), firmware-downloading(13), make-busy-mode(14), service-line(15), non-answering-modem(16), short-holding-time-modem(17), sub-tree-truncation(18), tdm-failure-good-apl(19), trib-timeout(20), dial-tone(21), redundant-power(22), no-response(31)" ::= { devStatus 3 } devStatusAlertDesc OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Contains current Primary Alerts for the device, in text format, delimited by semicolons (;). The following abbreviations are used for the primary alerts: Fail, CfgChng, Test, Disab, Thresh, FacAlrm, ExtAlrm, StrTerm, AccSec, DialBkUp, DteAlrm, SubSpeed, PriChIr, FwDnLd, MkBusy, Service, NoAns, ShrtHld, SubTrunc, TdmFail(GoodApl), TribTO, DTone, Power, NoResp" ::= { devStatus 4 } devStatusState OBJECT-TYPE SYNTAX INTEGER { idle-or-leased(1), ring-indicate(2), answering(3), talk-mode(4), off-hook(5), dialing(6), remote-ringing(7), on-line(8), dial-backup(9), dial-standby(10) } ACCESS read-only STATUS mandatory DESCRIPTION "The current state of the device." ::= { devStatus 5 } devStatusSpeed OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The current data rate of the device, in bits per second. A value of zero indicates that the device is training." ::= { devStatus 6 } devStatusCtrlTrib OBJECT-TYPE SYNTAX INTEGER { local-control(1), remote-control(2), tributary(3), other(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the position of the device in the network." ::= { devStatus 7 } devStatusConfigType OBJECT-TYPE SYNTAX INTEGER { leased(1), dial(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the configured mode of the device." ::= { devStatus 8 } devStatusPollingState OBJECT-TYPE SYNTAX INTEGER { active(1), inactive(2), inventory(3), suspended(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the polling state of the device in the network." ::= { devStatus 9 } -- The following status objects are new for Rel 2.0 devStatusLockingState OBJECT-TYPE SYNTAX INTEGER { available(1), locked(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the 6700 NMS locking state for the device." ::= { devStatus 10 } devStatusLockingTask OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Contains the name of the task that currently has a lock on the device, or null string if no lock." ::= { devStatus 11 } devStatusLockingIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Contains the IP address of the manager that currently has a lock on the device, or 0.0.0.0 if no lock." ::= { devStatus 12 } -- Circuit Quality Group (dev 4) -- Type Definition for Circuit Quality Validity indicators -- Validity is not-used(6) if not supported by device type. CirQualValidity ::= INTEGER { valid(1), valid-greater-than(2), valid-less-than(3), not-valid-for-modulation-mode(4), not-valid-for-multipoint-mode(5), not-available-yet(6), count-overflow(7), not-used(8) } -- Bit Error Rate devCirQualBitErrorRateValidity OBJECT-TYPE SYNTAX CirQualValidity ACCESS read-only STATUS mandatory DESCRIPTION "Validity of the devCirQualBitErrorRate object." ::= { devCirQual 1 } devCirQualBitErrorRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Bit error rate. Expressed as errors per billion (1E9) bits." ::= { devCirQual 2 } -- Mean Squared Error devCirQualMeanSquareErrorValidity OBJECT-TYPE SYNTAX CirQualValidity ACCESS read-only STATUS mandatory DESCRIPTION "Validity of the devCirQualMeanSquareError object." ::= { devCirQual 3 } devCirQualMeanSquareError OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Mean squared error." ::= { devCirQual 4 } -- Receive Level devCirQualReceiveLevelValidity OBJECT-TYPE SYNTAX CirQualValidity ACCESS read-only STATUS mandatory DESCRIPTION "Validity of the devCirQualReceiveLevel object." ::= { devCirQual 5 } devCirQualReceiveLevel OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Receive level. Units are (dBm *10). Possible range is -204.7 to +204.7 dBm." ::= { devCirQual 6 } -- 1004 Hz Loss devCirQualHzLoss1004Validity OBJECT-TYPE SYNTAX CirQualValidity ACCESS read-only STATUS mandatory DESCRIPTION "Validity of the devCirQualHzLoss1004 object." ::= { devCirQual 7 } devCirQualHzLoss1004 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1004 Hz loss." ::= { devCirQual 8 } -- Signal to Noise Ratio devCirQualSignalToNoiseValidity OBJECT-TYPE SYNTAX CirQualValidity ACCESS read-only STATUS mandatory DESCRIPTION "Validity of the devCirQualSignalToNoise object." ::= { devCirQual 9 } devCirQualSignalToNoise OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Signal to noise ratio. Units are (dB * 10). Possible range is 0.0 to 102.3 dB." ::= { devCirQual 10 } -- Phase Jitter 0-20 Hz devCirQualPhaseJitter20Validity OBJECT-TYPE SYNTAX CirQualValidity ACCESS read-only STATUS mandatory DESCRIPTION "Validity of the devCirQualPhaseJitter20 object." ::= { devCirQual 11 } devCirQualPhaseJitter20 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Phase jitter 0-20 Hz. Units are (degrees * 10). Possible range 0.0 to 33 degrees." ::= { devCirQual 12 } -- Phase Jitter 20-300 Hz devCirQualPhaseJitter300Validity OBJECT-TYPE SYNTAX CirQualValidity ACCESS read-only STATUS mandatory DESCRIPTION "Validity of the devCirQualPhaseJitter300 object." ::= { devCirQual 13 } devCirQualPhaseJitter300 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Phase jitter 20-300 Hz. Units are (degrees * 10). Possible range 0.0 to 33 degrees." ::= { devCirQual 14 } -- Positive Attenuation devCirQualPositiveAttenuationValidity OBJECT-TYPE SYNTAX CirQualValidity ACCESS read-only STATUS mandatory DESCRIPTION "Validity of the devCirQualPositiveAttenuation object." ::= { devCirQual 15 } devCirQualPositiveAttenuation OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Positive attenuation." ::= { devCirQual 16 } -- Negative Attenuation devCirQualNegativeAttenuationValidity OBJECT-TYPE SYNTAX CirQualValidity ACCESS read-only STATUS mandatory DESCRIPTION "Validity of the devCirQualNegativeAttenuation object." ::= { devCirQual 17 } devCirQualNegativeAttenuation OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Negative attenuation." ::= { devCirQual 18 } -- Envelope Delay devCirQualEnvelopeDelayValidity OBJECT-TYPE SYNTAX CirQualValidity ACCESS read-only STATUS mandatory DESCRIPTION "Validity of the devCirQualEnvelopeDelay object." ::= { devCirQual 19 } devCirQualEnvelopeDelay OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Envelope delay." ::= { devCirQual 20 } -- Frequency Offset devCirQualFrequencyOffsetValidity OBJECT-TYPE SYNTAX CirQualValidity ACCESS read-only STATUS mandatory DESCRIPTION "Validity of the devCirQualFrequencyOffset object." ::= { devCirQual 21 } devCirQualFrequencyOffset OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Frequency offset. Units are (Hz * 10). Possible range -51.1 to +51.1 Hz." ::= { devCirQual 22 } -- Non Linear Distortion devCirQualNonLinearDistortionValidity OBJECT-TYPE SYNTAX CirQualValidity ACCESS read-only STATUS mandatory DESCRIPTION "Validity of the devCirQualNonLinearDistortion object." ::= { devCirQual 23 } devCirQualNonLinearDistortion OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Non-linear distortion. Units are negative tenths of dB. Possible range -0.0 to -102.3 dB. Example: -20 dB is encoded as integer -200." ::= { devCirQual 24 } -- Retrains devCirQualRetrainsValidity OBJECT-TYPE SYNTAX CirQualValidity ACCESS read-only STATUS mandatory DESCRIPTION "Validity of the devCirQualRetrains object." ::= { devCirQual 25 } devCirQualRetrains OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Retrains. Integer value represents the number of retrain events during the last 15 minutes. Possible range is 0 to 4095." ::= { devCirQual 26 } -- Blown Startups devCirQualBlownStartupsValidity OBJECT-TYPE SYNTAX CirQualValidity ACCESS read-only STATUS mandatory DESCRIPTION "Validity of the devCirQualBlownStartups object." ::= { devCirQual 27 } devCirQualBlownStartups OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blown startups." ::= { devCirQual 28 } -- Gain Hits devCirQualGainHitsValidity OBJECT-TYPE SYNTAX CirQualValidity ACCESS read-only STATUS mandatory DESCRIPTION "Validity of the devCirQualGainHits object." ::= { devCirQual 29 } devCirQualGainHits OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Gain hits. Integer value represents the number of gain hit events during last 15 minutes. Possible range: 0 to 4095." ::= { devCirQual 30 } -- Phase Hits devCirQualPhaseHitsValidity OBJECT-TYPE SYNTAX CirQualValidity ACCESS read-only STATUS mandatory DESCRIPTION "Validity of the devCirQualPhaseHits object." ::= { devCirQual 31 } devCirQualPhaseHits OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Phase hits. Integer value represents the number of phase hit events during the last 15 minutes. Possible range is 0 to 4095." ::= { devCirQual 32 } -- Impulse Noise devCirQualImpulseNoiseValidity OBJECT-TYPE SYNTAX CirQualValidity ACCESS read-only STATUS mandatory DESCRIPTION "Validity of the devCirQualImpulseNoise object." ::= { devCirQual 33 } devCirQualImpulseNoise OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Impulse noise. Integer value represents the number of impulse noise events during the last 15 minutes. Possible range is 0 to 4095." ::= { devCirQual 34 } -- Dropouts devCirQualDropoutsValidity OBJECT-TYPE SYNTAX CirQualValidity ACCESS read-only STATUS mandatory DESCRIPTION "Validity of the devCirQualDropouts object." ::= { devCirQual 35 } devCirQualDropouts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Dropouts. Integer value represents the number of dropout events during the last 15 minutes. Possible range is 0 to 4095." ::= { devCirQual 36 } -- Line Quality devCirQualLineQualityValidity OBJECT-TYPE SYNTAX CirQualValidity ACCESS read-only STATUS mandatory DESCRIPTION "Validity of the devCirQualLineQuality object." ::= { devCirQual 37 } devCirQualLineQuality OBJECT-TYPE SYNTAX INTEGER { excellent(1), good(2), fair(3), poor(4), no-signal(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Line (signal) quality." ::= { devCirQual 38 } -- Near End Echo devCirQualNearEndEchoValidity OBJECT-TYPE SYNTAX CirQualValidity ACCESS read-only STATUS mandatory DESCRIPTION "Validity of the devCirQualNearEndEcho object." ::= { devCirQual 39 } devCirQualNearEndEcho OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Near end echo. Units are (dB *10). Possible range 0.0 to -102.4 dB." ::= { devCirQual 40 } -- Far End Echo devCirQualFarEndEchoValidity OBJECT-TYPE SYNTAX CirQualValidity ACCESS read-only STATUS mandatory DESCRIPTION "Validity of the devCirQualFarEndEcho object." ::= { devCirQual 41 } devCirQualFarEndEcho OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Far end echo. Units are (dB * 10). Possible range 0.0 to -102.4 dB." ::= { devCirQual 42 } -- Far End Delay devCirQualFarEndDelayValidity OBJECT-TYPE SYNTAX CirQualValidity ACCESS read-only STATUS mandatory DESCRIPTION "Validity of the devCirQualFarEndDelay object." ::= { devCirQual 43 } devCirQualFarEndDelay OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Far end delay. Units are in milliseconds. Possible range 0 to 4095 ms." ::= { devCirQual 44 } -- Echo Frequency Offset devCirQualEchoFreqOffsetValidity OBJECT-TYPE SYNTAX CirQualValidity ACCESS read-only STATUS mandatory DESCRIPTION "Validity of the devCirQualEchoFreqOffset object." ::= { devCirQual 45 } devCirQualEchoFreqOffset OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Echo frequency offset. Units are tenths of Hertz. Possible range -51.1 to 51.1 Hz." ::= { devCirQual 46 } -- EIA Status Group (dev 5) -- Textual Convention for EIA Status Integer EIAStatus ::= INTEGER { off(1), on(2), unsupported-lead(3), lead-changing(4) } -- Number of Ports (Number of Entries in EIA Status Table) devEIAStatusPorts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of ports present in the device and the number of entries in the devEIAStatusTable." ::= { devEIAStatus 1 } -- EIA Status Table devEIAStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF DevEIAStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of EIA status values for each port." ::= { devEIAStatus 2 } devEIAStatusEntry OBJECT-TYPE SYNTAX DevEIAStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A port entry in the EIA status table." INDEX { devEIAStatusIndex } ::= { devEIAStatusTable 1 } -- Layout of one entry in devEIAStatusTable. DevEIAStatusEntry ::= SEQUENCE { devEIAStatusIndex INTEGER, devEIAStatusCode OCTET STRING, devEIAStatusDTR EIAStatus, devEIAStatusTD EIAStatus, devEIAStatusRD EIAStatus, devEIAStatusDSR EIAStatus, devEIAStatusRTS EIAStatus, devEIAStatusCTS EIAStatus, devEIAStatusDCD EIAStatus, devEIAStatusTM EIAStatus, devEIAStatusDRI EIAStatus, devEIAStatusPIN13 EIAStatus, devEIAStatusPIN19 EIAStatus, devEIAStatusDRS EIAStatus, devEIAStatusLL EIAStatus, devEIAStatusRL EIAStatus, devEIAStatusRI EIAStatus, devEIAStatusDPR EIAStatus, devEIAStatusDLO EIAStatus, devEIAStatusCRQ EIAStatus, devEIAStatusACR EIAStatus, devEIAStatusDSC EIAStatus, devEIAStatusPND EIAStatus } devEIAStatusIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of the entry in the devEIAStatusTable. Note that the device hardware port number is used as the index. Port numbers start with 1 and increment monotonically up to number of ports in devEIAStatusPorts." ::= { devEIAStatusEntry 1 } devEIAStatusCode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (6)) ACCESS read-only STATUS mandatory DESCRIPTION "This object contains the combined status of all 21 EIA leads, in a compressed format which uses 2 bits for each EIA lead, ordered left to right, as occurring below. The status encoding is specified in binary as follows: off=00; on=01; unsupported-lead=10; lead-changing=11." ::= { devEIAStatusEntry 2 } -- 21 EIA status objects devEIAStatusDTR OBJECT-TYPE SYNTAX EIAStatus ACCESS read-only STATUS mandatory DESCRIPTION "DTR" ::= { devEIAStatusEntry 3 } devEIAStatusTD OBJECT-TYPE SYNTAX EIAStatus ACCESS read-only STATUS mandatory DESCRIPTION "TD." ::= { devEIAStatusEntry 4 } devEIAStatusRD OBJECT-TYPE SYNTAX EIAStatus ACCESS read-only STATUS mandatory DESCRIPTION "RD." ::= { devEIAStatusEntry 5 } devEIAStatusDSR OBJECT-TYPE SYNTAX EIAStatus ACCESS read-only STATUS mandatory DESCRIPTION "DSR." ::= { devEIAStatusEntry 6 } devEIAStatusRTS OBJECT-TYPE SYNTAX EIAStatus ACCESS read-only STATUS mandatory DESCRIPTION "RTS." ::= { devEIAStatusEntry 7 } devEIAStatusCTS OBJECT-TYPE SYNTAX EIAStatus ACCESS read-only STATUS mandatory DESCRIPTION "CTS." ::= { devEIAStatusEntry 8 } devEIAStatusDCD OBJECT-TYPE SYNTAX EIAStatus ACCESS read-only STATUS mandatory DESCRIPTION "DCD." ::= { devEIAStatusEntry 9 } devEIAStatusTM OBJECT-TYPE SYNTAX EIAStatus ACCESS read-only STATUS mandatory DESCRIPTION "TM." ::= { devEIAStatusEntry 10 } devEIAStatusDRI OBJECT-TYPE SYNTAX EIAStatus ACCESS read-only STATUS mandatory DESCRIPTION "DRI." ::= { devEIAStatusEntry 11 } devEIAStatusPIN13 OBJECT-TYPE SYNTAX EIAStatus ACCESS read-only STATUS mandatory DESCRIPTION "Pin13." ::= { devEIAStatusEntry 12 } devEIAStatusPIN19 OBJECT-TYPE SYNTAX EIAStatus ACCESS read-only STATUS mandatory DESCRIPTION "Pin19." ::= { devEIAStatusEntry 13 } devEIAStatusDRS OBJECT-TYPE SYNTAX EIAStatus ACCESS read-only STATUS mandatory DESCRIPTION "DRS." ::= { devEIAStatusEntry 14 } devEIAStatusLL OBJECT-TYPE SYNTAX EIAStatus ACCESS read-only STATUS mandatory DESCRIPTION "LL." ::= { devEIAStatusEntry 15 } devEIAStatusRL OBJECT-TYPE SYNTAX EIAStatus ACCESS read-only STATUS mandatory DESCRIPTION "RL." ::= { devEIAStatusEntry 16 } devEIAStatusRI OBJECT-TYPE SYNTAX EIAStatus ACCESS read-only STATUS mandatory DESCRIPTION "RI." ::= { devEIAStatusEntry 17 } devEIAStatusDPR OBJECT-TYPE SYNTAX EIAStatus ACCESS read-only STATUS mandatory DESCRIPTION "DPR." ::= { devEIAStatusEntry 18 } devEIAStatusDLO OBJECT-TYPE SYNTAX EIAStatus ACCESS read-only STATUS mandatory DESCRIPTION "DLO." ::= { devEIAStatusEntry 19 } devEIAStatusCRQ OBJECT-TYPE SYNTAX EIAStatus ACCESS read-only STATUS mandatory DESCRIPTION "CRQ." ::= { devEIAStatusEntry 20 } devEIAStatusACR OBJECT-TYPE SYNTAX EIAStatus ACCESS read-only STATUS mandatory DESCRIPTION "ACR." ::= { devEIAStatusEntry 21 } devEIAStatusDSC OBJECT-TYPE SYNTAX EIAStatus ACCESS read-only STATUS mandatory DESCRIPTION "DSC." ::= { devEIAStatusEntry 22 } devEIAStatusPND OBJECT-TYPE SYNTAX EIAStatus ACCESS read-only STATUS mandatory DESCRIPTION "PND." ::= { devEIAStatusEntry 23 } -- External Leads Group (dev 6) -- Textual Convention for External Lead objects ExternalLead ::= INTEGER { lead-off(1), lead-on(2) } devExtLeadsOutputA OBJECT-TYPE SYNTAX ExternalLead ACCESS read-write STATUS mandatory DESCRIPTION "For 3500/3600 series devices, the Output A port is connected to RS-232 output pin 12 of port 1. For 3800/3900 series devices, the Output A port is connected to stand-alone models only on RS-232 output pin 16 of port 1." ::= { devExtLeads 1 } devExtLeadsOutputB OBJECT-TYPE SYNTAX ExternalLead ACCESS read-write STATUS mandatory DESCRIPTION "For 3500/3600 series devices, the Output B port is connected to RS-232 output pin 13 of port 1. For 3800/3900 series devices, the Output B port is connected to stand-alone models only on RS-232 output pin 13 of port 1." ::= { devExtLeads 2 } devExtLeadsInputA OBJECT-TYPE SYNTAX ExternalLead ACCESS read-only STATUS mandatory DESCRIPTION "For 3500/3600 series devices, the Input A port is connected to RS-232 input pin 19 of port 1. For 3800/3900 series devices, the Input A port is connected to stand-alone models only on RS-232 input pin 19 of port 1." ::= { devExtLeads 3 } devExtLeadsInputB OBJECT-TYPE SYNTAX ExternalLead ACCESS read-only STATUS mandatory DESCRIPTION "For 3500/3600 series devices, the Input B port is connected to RS-232 input pin 23 of port 1. For 3800/3900 series devices, the Input B port is connected to stand-alone models only on RS-232 input pin 14 of port 1." ::= { devExtLeads 4 } -- Command Group (dev 7) -- Dial an Entered or Stored Number devCommandDial OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) ACCESS read-write STATUS mandatory DESCRIPTION "Setting this attribute will cause the modem to dial the entered number. To dial a stored number, the string must begin with 'd', followed by the call directory entry number. This variable will always return a zero-length string." ::= { devCommand 1 } -- Disconnect Call or Service devCommandDisconnect OBJECT-TYPE SYNTAX INTEGER { disconnect-call(1), disconnect-service(2), unknown(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this attribute to disconnect-call(1) will cause the current call to be disconnected. Setting this attribute to disconnect-service(2) will cause service disconnect. This object will always return a value of unknown(3)." ::= { devCommand 2 } -- Change Busy State devCommandBusy OBJECT-TYPE SYNTAX INTEGER { set-busy(1), clear-busy(2), unknown(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this attribute to busy(1) will cause the device to busy out the attached analog phone line. Setting this attribute to clear(2) will cause the device to unbusy the analog phone line. This object will always return a value of unknown(3). To test the current busy state, refer to the devStatusAlert object." ::= { devCommand 3 } -- Switch To Dial-Backup/Dial-Standby/Service-Line devCommandSwitchTo OBJECT-TYPE SYNTAX INTEGER { dial-backup(1), dial-standby(2), leased(3), service-line(4), -- switch for mgmt mode unknown(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Switch service mode to dial-backup(1), dial-standby(2), leased (3), or service-line(4). This object always returns a value of unknown(5)." ::= { devCommand 4 } -- Enable/Disable Device devCommandEnable OBJECT-TYPE SYNTAX INTEGER { enable-device(1), disable-device(2), unknown(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Write to enable(1) or disable(2) the device. This object always returns a value of unknown(3)." ::= { devCommand 5 } -- Reset Device devCommandReset OBJECT-TYPE SYNTAX INTEGER { software(1), hardware(2), unknown(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Invoke a software(1) or hardware(2) reset of the device. This object always returns a value of unknown(3)." ::= { devCommand 6 } -- Send Message to Front Panel devCommandMessage OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) ACCESS read-write STATUS mandatory DESCRIPTION "Write to send a message string to the device. This object always returns a null string." ::= { devCommand 7 } -- Make All Members of Hunt Group Busy (Rel 2.0) devCommandGroupBusy OBJECT-TYPE SYNTAX INTEGER { set-group-busy(1), clear-group-busy(2), unknown(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this attribute to busy(1) will cause all devices in the addressed device's hunt group to busy-out their attached analog phone lines. Setting this attribute to clear(2) will cause the devices to unbusy their analog phone lines. This object will always return a value of unknown(3)." ::= { devCommand 8 } -- Force Device Unlock (Rel 2.0) devCommandForceUnlock OBJECT-TYPE SYNTAX INTEGER { force-unlock(1), unknown(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Forces off a device lock when set to force-unlock(1). When read, this object always returns a value of unknown(2)." ::= { devCommand 9 } -- Clear Alarm on 6700 (Rel 2.0) devCommandClearAlarm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Set to the specific trap identifier of alarm to clear. Always returns zero when read. Note that most alarms persist despite clearing until the problem is resolved." ::= { devCommand 10 } END 6700-TRAPS DEFINITIONS ::= BEGIN -- Title: COMSPHERE 6700 Trap Definitions -- Release: 2.0.0 (3/3/97) ** PROPOSED ** -- -- Copyright (C) 1994-1997, Paradyne Corp. All rights reserved. -- -- This file may be freely copied and distributed as -- long as no changes are made to it. IMPORTS TRAP-TYPE FROM RFC-1215 nms-6700-products FROM ATTDCE-MIB; -- -- Enterprise Identification for COMSPHERE 6700 SNMP Proxy Agent Traps -- att67nmsOid OBJECT IDENTIFIER ::= { nms-6700-products 1 } -- NMS OID att67devOid OBJECT IDENTIFIER ::= { nms-6700-products 2 } -- Devices att67dialOid OBJECT IDENTIFIER ::= { att67devOid 1 } -- Dial OID att67aplOid OBJECT IDENTIFIER ::= { att67devOid 2 } -- APL OID att67dsuOid OBJECT IDENTIFIER ::= { att67devOid 3 } -- DSU OID -- Dial Device Alerts att67cDevFail TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "Device failure." ::= 1 att67cConfigChg TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "Configuration change notification received from device." ::= 2 att67cTestMode TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "Test mode." ::= 3 att67cDevDisable TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "Device has been disabled." ::= 4 att67cVFExceed TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "VF parameter threshold exceeded." ::= 5 att67cFacility TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "Facility alarm." ::= 6 att67cExternal TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "External alarm." ::= 7 att67cStreaming TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "Streaming terminal." ::= 8 att67cSecurity TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "Access security alarm." ::= 9 att67cDialBackup TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "Dial backup active for APL." ::= 10 att67cDTE TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "DTE alarm." ::= 11 att67cSubSpeed TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "Sub-normal operating speed." ::= 12 att67cPrimeChannel TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "Primary channel interrupted. Reason for interruption is remote access using the primary channel. Source of interruption is front panel or network management." ::= 13 att67cFWDownload TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "Firmware downloading." ::= 14 att67cMakeBusyMode TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "Make busy mode." ::= 15 att67cServiceLine TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "Service line." ::= 16 att67cNonAnswering TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "Non-answering modem." ::= 17 att67cShortHold TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "Short holding time modem." ::= 18 att67cNoResponse TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "No response from the device." ::= 32 att67cVFLogin TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "VF login OK. The calling party entered a correct VF (DTMF) password." ::= 101 att67cUserLogin TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "User Login OK. The calling party entered a correct user password" ::= 102 att67cLoginRetry TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "User Login Rejected - Retry Failed. The calling party entered an excessive number of wrong passwords." ::= 103 att67cLoginTimeout TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "User Login Rejected - Password Timeout. The calling party failed to enter a user password within the allotted time." ::= 104 att67cLoginDisconnect TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "User Login Aborted - Line Disconnected. The calling party disconnected before user login completed." ::= 105 att67cVFInvalid TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "VF Login Rejected - Password Invalid. The calling party entered an incorrect VF (DTMF) password." ::= 106 att67cVFTimeout TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "VF Login Rejected - Password Timeout. The calling party failed to enter a VF (DTMF) password within the allotted time." ::= 107 att67cVFDisconnect TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "VF Login Aborted - Line Disconnected. The calling party disconnected before VF (DTMF) login completed." ::= 108 att67cUserRetries TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "User Login OK - Multiple Password Retries. The calling party has successfully completed user login, after multiple attempts." ::= 109 att67cUserBadCombo TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "User Login Rejected - Invalid Combination. The calling party entered an invalid user-id and password combination." ::= 110 att67cUserBadId TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "User Login Rejected - Invalid User ID. The calling party entered an invalid user-id (however the password was valid for the device)." ::= 111 att67cUserBadTime TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "User Login Rejected - Invalid Access Time. The calling party entered a user-id for which access is not permitted at the current time." ::= 112 att6cUserHack TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "User Login Hack - Multiple Sequential Password Retries. The password retry pattern indicates a hacker is attempting to defeat login security." ::= 113 att67cSecTable TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "Device Security Table Invalid." ::= 114 att67cSecDownload TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "Security Download Failed." ::= 116 att67cSecFrontPanel TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "Security Front Panel Modification. Security configuration has been modified from the device front panel." ::= 117 att67cDevFailClr TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "Device failure cleared." ::= 201 att67cConfigChgClr TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "Configuration change notify cleared." ::= 202 att67cTestModeClr TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "Test mode cleared." ::= 203 att67cDevDisableClr TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "Device disabled cleared." ::= 204 att67cVFExceedClr TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "VF parameter threshold exceeded cleared." ::= 205 att67cFacilityClr TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "Facility alarm cleared." ::= 206 att67cExternalClr TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "External alarm cleared." ::= 207 att67cStreamingClr TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "Streaming terminal cleared." ::= 208 att67cSecurityClr TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "Access security alarm cleared." ::= 209 att67cDialBackupClr TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "Dial backup active for APL cleared." ::= 210 att67cDTEClr TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "DTE alarm." ::= 211 att67cSubSpeedClr TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "Sub-normal operating speed cleared." ::= 212 att67cPrimeChannelClr TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "Primary channel interrupted cleared." ::= 213 att67cFWDownloadClr TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "Firmware downloading cleared." ::= 214 att67cMakeBusyModeClr TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "Make busy mode cleared." ::= 215 att67cServiceLineClr TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "Service line mode cleared." ::= 216 att67cNonAnsweringClr TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "Non-answering modem cleared." ::= 217 att67cShortHoldClr TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "Short holding time modem cleared." ::= 218 att67NoResponseClr TRAP-TYPE ENTERPRISE att67dialOid DESCRIPTION "No response from the device cleared." ::= 232 -- APL Device Traps att67aDevFail TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Device failure." ::= 1 att67aConfigChg TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Configuration change notification received from device." ::= 2 att67aTestMode TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Test mode." ::= 3 att67aDevDisable TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Device has been disabled." ::= 4 att67aVFExceed TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "VF parameter threshold exceeded." ::= 5 att67aFacility TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Facility alarm." ::= 6 att67aExternal TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "External alarm." ::= 7 att67aStreaming TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Streaming terminal." ::= 8 att67aSecurity TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Access security alarm." ::= 9 att67aDialBackup TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Dial backup active for APL." ::= 10 att67aDTE TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "DTE alarm." ::= 11 att67aSubSpeed TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Sub-normal operating speed." ::= 12 att67aPrimeChannel TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Primary channel interrupted. Reason for interruption is remote access using the primary channel. Source of interruption is front panel or network management." ::= 13 att67aFWDownload TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Firmware downloading." ::= 14 att67aMakeBusyMode TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Make busy mode." ::= 15 att67aServiceLine TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Service line." ::= 16 att67aNonAnswering TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Non-answering modem." ::= 17 att67aShortHold TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Short holding time modem." ::= 18 att67aSubTreeTrunc TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Sub-tree truncation due to excessive alarms." ::= 19 att67aGoodApl TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Good APL line detected while on backup (dial or dual lease line)." ::= 20 att67aNoResponse TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "No response from the device." ::= 32 att67cRxLevHigh TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Receive level high threshold alarm." ::= 33 att67cRxLevLow TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Receive level low threshold alarm." ::= 34 att67cSignalNoise TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Signal/Noise ratio threshold alarm." ::= 35 att67cPhaseJitter TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Phase jitter threshold alarm." ::= 36 att67cFreqOffset TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Frequency Offset threshold alarm." ::= 37 att67cNonLinearD TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Non-linear distortion threshold alarm." ::= 38 att67cRetrain TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Retrain threshold alarm." ::= 39 att67cSignalQual TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Signal Quality threshold alarm." ::= 40 att67cNearEcho TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Near Echo threshold alarm." ::= 41 att67cFarEcho TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Far Echo threshold alarm." ::= 42 att67cP1RxData TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 1 Receive Data alarm." ::= 43 att67cP1TxData TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 1 Transmit Data alarm." ::= 44 att67cP1DTR TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 1 DTR alarm." ::= 45 att67cP1CTS TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 1 CTS alarm." ::= 46 att67cP1RTS TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 1 RTS alarm." ::= 47 att67cP1DSR TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 1 DSR alarm." ::= 48 att67cP1LSD TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 1 LSD alarm." ::= 49 att67cP1AutoStrDis TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 1 auto stream diabled alarm." ::= 50 att67cP1Disabled TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 1 disabled alarm." ::= 51 att67cP2RxData TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 2 Receive Data alarm." ::= 52 att67cP2TxData TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 2 Transmit Data alarm." ::= 53 att67cP2DTR TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 2 DTR alarm." ::= 54 att67cP2CTS TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 2 CTS alarm." ::= 55 att67cP2RTS TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 2 RTS alarm." ::= 56 att67cP2DSR TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 2 DSR alarm." ::= 57 att67cP2LSD TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 2 LSD alarm." ::= 58 att67cP2AutoStrDis TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 2 auto stream diabled alarm." ::= 59 att67cP2Disable TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 2 disabled alarm." ::= 60 att67cP3RxData TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 3 Receive Data alarm." ::= 61 att67cP3TxData TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 3 Transmit Data alarm." ::= 62 att67cP3DTR TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 3 DTR alarm." ::= 63 att67cP3CTS TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 3 CTS alarm." ::= 64 att67cP3RTS TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 3 RTS alarm." ::= 65 att67cP3DSR TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 3 DSR alarm." ::= 66 att67cP3LSD TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 3 LSD alarm." ::= 67 att67cP3AutoStrDis TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 3 auto stream diabled alarm." ::= 68 att67cP3Disable TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 3 disabled alarm." ::= 69 att67cP4RxData TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 4 Receive Data alarm." ::= 70 att67cP4TxData TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 4 Transmit Data alarm." ::= 71 att67cP4DTR TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 4 DTR alarm." ::= 72 att67cP4CTS TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 4 CTS alarm." ::= 73 att67cP4RTS TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 4 RTS alarm." ::= 74 att67cP4DSR TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 4 DSR alarm." ::= 75 att67cP4LSD TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 4 LSD alarm." ::= 76 att67cP4AutoStrDis TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 4 auto stream diabled alarm." ::= 77 att67cP4Disable TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 4 disabled alarm." ::= 78 att67aVFLogin TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "VF login OK. The calling party entered a correct VF (DTMF) password." ::= 101 att67aUserLogin TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "User Login OK. The calling party entered a correct user password" ::= 102 att67aLoginRetry TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "User Login Rejected - Retry Failed. The calling party entered an excessive number of wrong passwords." ::= 103 att67aLoginTimeout TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "User Login Rejected - Password Timeout. The calling party failed to enter a user password within the allotted time." ::= 104 att67aLoginDisconnect TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "User Login Aborted - Line Disconnected. The calling party disconnected before user login completed." ::= 105 att67aVFInvalid TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "VF Login Rejected - Password Invalid. The calling party entered an incorrect VF (DTMF) password." ::= 106 att67aVFTimeout TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "VF Login Rejected - Password Timeout. The calling party failed to enter a VF (DTMF) password within the allotted time." ::= 107 att67aVFDisconnect TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "VF Login Aborted - Line Disconnected. The calling party disconnected before VF (DTMF) login completed." ::= 108 att67aUserRetries TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "User Login OK - Multiple Password Retries. The calling party has successfully completed user login, after multiple attempts." ::= 109 att67aUserBadCombo TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "User Login Rejected - Invalid Combination. The calling party entered an invalid user-id and password combination." ::= 110 att67aUserBadId TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "User Login Rejected - Invalid User ID. The calling party entered an invalid user-id (however the password was valid for the device)." ::= 111 att67aUserBadTime TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "User Login Rejected - Invalid Access Time. The calling party entered a user-id for which access is not permitted at the current time." ::= 112 att67aUserHack TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "User Login Hack - Multiple Sequential Password Retries. The password retry pattern indicates a hacker is attempting to defeat login security." ::= 113 att67aSecTable TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Device Security Table Invalid." ::= 114 att67aSecDownload TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Security Download Failed." ::= 116 att67aSecFrontPanel TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Security Front Panel Modification. Security configuration has been modified from the device front panel." ::= 117 att67aDevFailClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Device failure cleared." ::= 201 att67aConfigChgClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Configuration change notify cleared." ::= 202 att67aTestModeClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Test mode cleared." ::= 203 att67aDevDisableClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Device disabled cleared." ::= 204 att67aVFExceedClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "VF parameter threshold exceeded cleared." ::= 205 att67aFacilityClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Facility alarm cleared." ::= 206 att67aExternalClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "External alarm cleared." ::= 207 att67aStreamingClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Streaming terminal cleared." ::= 208 att67aSecurityClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Access security alarm cleared." ::= 209 att67aDialBackupClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Dial backup active for APL cleared." ::= 210 att67aDTEClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "DTE alarm." ::= 211 att67aSubSpeedClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Sub-normal operating speed cleared." ::= 212 att67aPrimeChannelClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Primary channel interrupted cleared." ::= 213 att67aFWDownloadClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Firmware downloading cleared." ::= 214 att67aMakeBusyModeClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Make busy mode cleared." ::= 215 att67aServiceLineClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Service line mode cleared." ::= 216 att67aNonAnsweringClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Non-answering modem cleared." ::= 217 att67aShortHoldClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Short holding time modem cleared." ::= 218 att67aSubTreeTruncClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Sub-tree truncation cleared." ::= 219 att67aGoodAplClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Good APL line cleared." ::= 220 att67aNoResponseClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "No response from the device cleared." ::= 232 att67cRxLevHighClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Receive level high threshold alarm cleared." ::= 233 att67cRxLevLowClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Receive level low threshold alarm cleared." ::= 234 att67cSignalNoiseClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Signal/Noise ratio threshold alarm cleared." ::= 235 att67cPhaseJitterClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Phase jitter threshold alarm cleared." ::= 236 att67cFreqOffsetClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Frequency Offset threshold alarm cleared." ::= 237 att67cNonLinearDClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Non-linear distortion threshold alarm cleared." ::= 238 att67cRetrainClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Retrain threshold alarm cleared." ::= 239 att67cSignalQualClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Signal Quality threshold alarm cleared." ::= 240 att67cNearEchoClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Near Echo threshold alarm cleared." ::= 241 att67cFarEchoClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Far Echo threshold alarm cleared." ::= 242 att67cP1RxDataClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 1 Receive Data alarm cleared." ::= 243 att67cP1TxDataClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 1 Transmit Data alarm cleared." ::= 244 att67cP1DTRClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 1 DTR alarm cleared." ::= 245 att67cP1CTSClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 1 CTS alarm cleared." ::= 246 att67cP1RTSClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 1 RTS alarm cleared." ::= 247 att67cP1DSRClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 1 DSR alarm cleared." ::= 248 att67cP1LSDClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 1 LSD alarm cleared." ::= 249 att67cP1AutoStrDisClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 1 auto stream diabled alarm cleared." ::= 250 att67cP1DisabledClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 1 disabled alarm cleared." ::= 251 att67cP2RxDataClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 2 Receive Data alarm cleared." ::= 252 att67cP2TxDataClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 2 Transmit Data alarm cleared." ::= 253 att67cP2DTRClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 2 DTR alarm cleared." ::= 254 att67cP2CTSClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 2 CTS alarm cleared." ::= 255 att67cP2RTSClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 2 RTS alarm cleared." ::= 256 att67cP2DSRClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 2 DSR alarm cleared." ::= 257 att67cP2LSDClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 2 LSD alarm cleared." ::= 258 att67cP2AutoStrDisClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 2 auto stream diabled alarm cleared." ::= 259 att67cP2DisableClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 2 disabled alarm cleared." ::= 260 att67cP3RxDataClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 3 Receive Data alarm cleared." ::= 261 att67cP3TxDataClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 3 Transmit Data alarm cleared." ::= 262 att67cP3DTRClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 3 DTR alarm cleared." ::= 263 att67cP3CTSClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 3 CTS alarm cleared." ::= 264 att67cP3RTSClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 3 RTS alarm cleared." ::= 265 att67cP3DSRClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 3 DSR alarm cleared." ::= 266 att67cP3LSDClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 3 LSD alarm cleared." ::= 267 att67cP3AutoStrDisClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 3 auto stream diabled alarm cleared." ::= 268 att67cP3DisableClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 3 disabled alarm cleared." ::= 269 att67cP4RxDataClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 4 Receive Data alarm cleared." ::= 270 att67cP4TxDataClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 4 Transmit Data alarm cleared." ::= 271 att67cP4DTRClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION "Port 4 DTR alarm cleared." ::= 272 att67cP4CTSClr TRAP-TYPE ENTERPRISE att67aplOid DESCRIPTION